Energy and Environmental
WhatsApp :+86-18144100983
NameDescriptionContent
  • Products related to categories: servo, frequency conversion, HMI, driver, distributed DCS, IPC (PC bus industrial computer), PLC (programmable control system), DCS (distributed control system), FCS (field bus system), robot and other products and technical services.
  • Applications: Wind energy, automobile, ship, transportation, manufacturing, aviation, petroleum, natural gas, thermal power, thermal power, nuclear energy, steel, metallurgy, mining, power and other industries
  • Controller PLC\Robot servo drive Electro-hydraulic servo valve\DCS system/Distributed control systemSystem rack\Communication adapter\Analog output\Analog input\
  • \Multi-meter energy meter\Ignition\circuit board\Crimp terminal\Electric ac drive\Low voltage DC power module\Electro-hydraulic\servo valve\Automatic control system\exchange\Network communication module
    controller\Processor module\dynamo\Electric machine\Servo drive\Touch screen\Input/output module\Water treatment monitoring system\Automobile\manufacturing system\Thermoelectric control system\
  • Digital output\Digital input\Mechanical protection system\High speed CPU
  • Electric power system\Chemical testing system\Petroleum control system\Tension monitoring system
  • DCS Distributed\control system\Steel control system\Steam\turbine system\Power generation system\
  • Thermal power generation system\Wind power system\Medium and high voltage frequency\conversion system\Precision motion system\Programmable control system\

E-mail

Password

Register Forgot password?
  • Singapore New Energy Corporation
  • Geylang Bahru Industrial Estate
  • การทางหลวงแห่งประเทศไทย
  • American Petroleum Group
  • Indian shipping works
  • Pakistan Gas Company
  • Russian Automotive Industry Corporation
  • Brazilian Mining Company
  • Bangladesh Hydro power Plant
  • Egyptian Iron and Steel Manufacturing Co
  • Groupe d’exploitation du métro français
  • Für meinen vater
  • BYD
  • Mongolia Wind Farm
  • Empresa venezolana de procesamiento de petróleo
  • alibaba
  • Sichuan Huayingshan Power Plant
  • Huadian Datong Power Plant
  • Guodian Shuangyashan Power Generation Co., Ltd.
  • Baosteel Group Xinjiang Bayi Steel Co., Ltd.
  • Guodian Changzhou Power Plant
  • Xingtai Iron and Steel Co., Ltd.
  • Guodian Fee County Power Generation Co., Ltd.
  • Yangzhou Second Power Plant
  • Sichuan Jintang Power Plant
  • Xingcheng Special Steel Co., Ltd.
  • Quzhou Yuanli Metal Products Co., Ltd.
  • Zijin Mining Group
  • (Bangladesh) Metro Construction Company
  • WuHan steel co., ltd.
  • MaAnShan  steel co., ltd.

ABB S800 I/O Modules and Termination Units

From:ABB | author:kongjiang | Release :2025-08-30 | 1910 view: | Share:

ABB S800 I/O Modules and Termination Units 

The S800 I/O is distributed as modular I/O that communicates with numerous

controllers over Advant Fieldbus 100 (AF100), PROFIBUS-DP, or directly.

The S800 I/O provides easy installation of the I/O modules and process cabling.

It is highly modularized and flexible so that I/O modules can be combined to suit

many applications. The S800 I/O can be mounted in many configurations to fit most

requirements.

The S800 I/O provides easy installation of the I/O modules and process cabling.

It is highly modularized and flexible so that the I/O modules can be combined to suit

many applications, including most types of signals, HART and Intrinsic Safety

Interface. The S800 I/O modules and a Fieldbus Communication Interface (FCI) are

combined to form an I/O Station. The S800 I/O can be used in both single and

redundant applications.

In general, all S800 units are G3 compliant. G3 compliant modules withstand more

severe environmental conditions according to ISA-S71.04. The following S800

units are G2 compliant - SD821, SD822, SD823, SD831, SD832, SD833, SD834,

SS822, SS832, TB811 and CI830. G3 compliant versions of SD822 and SS822 are

also available (refer to SD822Z and SS822Z).

All modules are marked with a bar code that shows the serial number, article ID and

the product revision number. A separate bar code strip is also enclosed along with

the module for placing on the module, if needed. The bar code is of type

Bar-code 128.

For more information, refer to S800 I/O Getting Started(3BSE020923*) manual.

The S800 I/O can be categorized into:

•Module Termination Units (MTU)

•I/O modules – S800 I/O modules and S800L I/O modules.

S800 I/O modules are designed to be used together with a Module Termination

Unit.

S800L I/O modules are designed to be directly mounted on a standard DIN rail.

The module also contains terminals for connections.

Module Termination Units and Terminal Units

The Module Termination Units (MTU) are passive base units used to house the I/O

modules. They contain the process wiring terminals and a section of the

ModuleBus.

The Module Termination Units (MTU) distributes the ModuleBus to the I/O module

and to the next MTU. It also generates the correct address to the I/O module by

shifting the outgoing position signals to the next MTU.

Two mechanical keys are used to configure the MTU for different types of I/O

modules. This is only a mechanical configuration and it does not affect the

functionality of the MTU or the I/O module. Each key has six positions, which gives

a total number of 36 different configurations. The configuration can be changed

with a screwdriver.

The MTU can be mounted on a standard DIN rail. It has a mechanical latch that

locks the MTU to the DIN rail. The latch can be released with a screwdriver.

The MTU has a mechanical locking mechanism that locks the module in its

position. This mechanism also gives the signal BLOCK to the I/O module that

keeps the module in its init state until it is locked in its position.

The top part of the MTU can be removed to replace the termination board even with

the system running. Such a need can be caused by a damaged terminal screw.

The MTUs are available in tree versions (Compact, Extended and Redundant).

The Compact MTU version typically provides for a compact installation of the I/O

modules using 1 wire connections.

TU805 Terminal Unit for 50 Volt Applications

The TU805 is a 16 channel terminal unit. Used to enable 2- and 3-wire connections

on DI801 or DO801. The Terminal Unit is mounted direct on DI801 or DO801.

TU810/TU810V1 Compact MTU for 50 Volt Applications

The TU810 is a 16 channel compact module termination unit. The TU810 has three

rows of terminals for field signals and process power connections.

TU811/TU811V1 Compact MTU for 250 Volt Applications

The TU811 is a 8 channel compact module termination unit. The TU811 has three

rows of terminals for field signals and process power connection.

TU812/TU812V1 Compact MTU for 50 Volt Applications and 25 pin D-sub for Process Connections

The TU812 is a 16 channel compact module termination unit. The TU812 has a 25

pin D-Sub connector for field signals and process power connections.

TU813 Compact MTU for 250 V Applications

The TU813 is a 8 channel compact module termination unit. The TU813 has three

rows of crimp snap-in connectors for field signals and process power connections.

TU814/TU814V1 Compact MTU for 50 Volt Applications The TU814 is a 16 channel compact module termination unit. The TU814 has three

rows of crimp snap-in connectors for field signals and process power connections.

TU818 Compact MTU for 50 Volt Applications

The TU818 is a 32 channel compact module termination unit. It consists of 40 pole

screw-terminals for process connections.

TU819 Compact MTU for 50 Volt Applications

The TU819 is a 32 channel compact module termination unit. It consists of two

D-sub 25 pole connector for field signals and process power connections, which

enables connection to the Phoenix Varioface, ABB interfast and so on.

TU830/TU830V1 Extended MTU for 50 Volt Applications The TU830 is a 16 channel extended module termination unit. The TU830 has three

rows of terminals for field signals and process power connection.

TU831/TU831V1 Extended MTU for 250 Volt Applications The TU831 is a 8 channel extended module termination unit. TU831 has two rows

of terminals for field signals and process power connection.

TU833 Extended MTU for 50 Volt Applications

The TU833 is a 16 channel extended module termination unit. The TU833 has three

rows of spring-case terminals for field signals and process power connection.

TU834 Extended MTU for 50 Volt Applications

The TU834 is a 8 channel extended module termination unit. The MTU has two

rows of terminals for field signals and process power connection. The MTU has

place for 8 replaceable shunt sticks (i.e one shunt stick per channel) for conversion

of the input current signal to a voltage signal.

TU835/TU835V1 Extended MTU, Individually Fused per Channel for 50 Volt Applications

The TU835 is a 8 channel extended module termination unit. The TU835 has two

rows of terminals for process power connection and a single row of field signal

connections. Each channel has one fused (3 A max.) transmitter power outlet

terminal and one signal terminal. Process voltage can be connected to 2 individually

isolated groups.

TU836/TU836V1 Extended MTU, Individually Fused per Channel for 250 Volt Applications

The TU836 is a 8 channel extended module termination unit. The TU836 has two

rows of terminals for field signals and process power connection. Each channel has

one fused (3 A max.) power outlet terminal and one signal return terminal. Process

voltage can be connected to 2 individually isolated groups.

TU837/TU837V1 Extended MTU, Individually Fused per Channel for 250 Volt Applications The TU837 is a 8 channel extended module termination unit. The TU837 has two

rows of terminals for field signals and process power connection. Each channel has

one fused (3 A max.) power outlet terminal and two signal terminals. Process

voltage return can be connected to two individually isolated groups.

TU838 Extended MTU, Individually Fused per Channel for 50 Volt Applications The TU838 is a 16 channel extended module termination unit. The TU838 has two

rows of terminals for field signals and process power connection. Each channel has

one fused (3 A max.) transmitter power outlet terminal and one signal terminal.

Process voltage can be connected to two individually isolated groups.

TU839 Extended MTU for 250 Volt Applications

The TU839 is a 8 channel extended module termination unit. TU839 has two rows

of terminals for field signals and process power connection. Each channel has one

sensor power outlet terminal and two signal terminals. Process voltage can be

connected to two individually isolated groups

TU842 Redundant Horizontal MTU for 50 V Applications

The TU842 is a 16 channel redundant module termination unit. The TU842 has

three rows of terminals for field signals and process power connection.It is intended

for mounting on a horizontal DIN rail. There is space on the MTU for two I/O

modules connected to separate ModuleBuses.

TU843 Redundant Vertical MTU for 50 V Applications

The TU843 is a 16 channel redundant module termination unit. The TU843 has

three rows of terminals for field signals and process power connection. It is intended

for mounting on a vertical DIN rail. There is space on the MTU for two I/O modules

connected to separate ModuleBuses.

TU844 Redundant Horizontal MTU for 50 V Applications

The TU844 is a 8 channel redundant module termination unit. The TU844 has two

rows of terminals for field signals and process power connection. It is a intended for

mounting on a horizontal DIN rail. The MTU has place for 8 replaceable shunt

sticks (i.e one shunt stick per channel) for conversion of the input current signal to a

voltage signal. There is space on the MTU for two I/O modules connected to

separate ModuleBuses.

TU845 Redundant Vertical MTU for 50 V Applications

The TU845 is a 8 channel redundant module termination unit. The TU845 has three

rows of terminals for field signals and process power connection. It is intended for

mounting on a vertical DIN rail. The MTU has place for 8 replaceable shunt sticks

(i.e one shunt stick per channel) for conversion of the input current signal to a

voltage signal. There is space on the MTU for two I/O modules connected to

separate ModuleBuses.

TU850 Extended MTU, Individually Current Limited and Disconnectable per Channel for 50 V Applications

The TU850 is a 16 channel extended module termination unit. TU850 has two rows

of terminals for field signals and process power connection. Each channel has one

current limited sensor/transmitter power outlet terminal and one signal terminal.

Process voltage can be connected to two individually isolated groups.

TU851 Extended MTU for 250 Volt Applications

The TU851 250V Extended MTU Which allows a maximum of 16 isolated I/O

channels and process voltage connections. It has a 32 pole screw-terminal for

process connections.

TU852 Redundant Horizontal MTU for 50 V Applications

The TU852 is a redundant module termination unit for up to 16 channels. The

TU852 has a two 25 pin D-Sub connector for field signals and process power

connections. It is a intended for mounting on a horizontal DIN rail. There is space

on the MTU for two I/O modules connected to separate Modulebuses.

TU854 Redundant Horizontal MTU for 50 V Applications

he TU854 is a 8 channel redundant module termination unit. The TU854 has a 25

pin D-Sub connector for field signals and process power connections. It is a

intended for mounting on a horizontal DIN rail. The MTU has place for 8

replaceable shunt sticks (i.e one shunt stick per channel) for conversion of the input

current signal to a voltage signal. There is space on the MTU for two I/O modules

connected to separate ModuleBuses.

TY801 Shunt Stick

The TY801 is a shunt stick for current or voltage signals together with AI845 or

AI880 and TU844 or TU845.

TY804 Shunt Stick

The TY804 is a shunt stick for NAMUR signals together with DP840 and TU844 or

TU845.

TY820 Temperature Sensor

The TY820 can be used with AI835/AI835A and AI843 to measure cold junction

temperature.

S800 I/O Modules

The I/O modules have open ventilated plastic enclosures. On the front of all I/O

modules there are at least three LEDs (FAULT, RUN and WARNING) indicating

the module status. Additionally some modules have LEDs indicating OSP or

PRIMARY, see Table 3 and Table 4.

I/O modules may be replaced in a fully operational I/O station. Mechanical keying

on modules and MTUs protect I/O modules from being inserted in positions where

they could be damaged by excessive voltage or current. An electronic type

designation ID in each module keeps the I/O module from being taken into

operation by the ModuleBus master, if a module’s ID doesn’t match the configured

module type definition. There are modules for both single and redundant

applications.

Refer to specifications in Appendix A, Specifications for more information.

AI810 Analog Input Module, 0...20 mA, 0...10 V

The AI810 Analog Input Module has 8 current and voltage inputs. The inputs are

independent for each channel, in that either voltage or current can be measured.

The current input is able to handle a short circuit to the transmitter supply without

damage. The input withstand HART communication.

Nominal input ranges are: 0(4)... +20 mA, 0(2)... +10 V.

AI815 Analog Input Module, 0..20mA, 0..5V, HART

The AI815 Analog Input Module has 8 analog inputs. The inputs can be configured

for voltage or current.

The module has HART pass-through functionality.

Nominal input ranges are: 0(4)...+20 mA, 0(1)...+5 V.

AI820 Differential Analog Input Module, +/- 20 mA, +/- 10 V, +/- 5 V

The AI820 Differential Analog Input Module has 4 differential, bipolar

current/voltage inputs. This module is suitable for applications requiring high

common mode rejection ratings, and/or bipolar voltage or current inputs. Nominal

input ranges are: -20...+20 mA, 0(4)...+20 mA, -10...+10 V, 0(2)...+10 V,

-5...+5 V and 0(1)...+5 V.

The current input is able to handle a short circuit to the transmitter supply without

damage. The input withstand HART communication.

AI825 Galvanic Isolated Analog Input Module, -20...+20 mA, 0(4)...+20 mA, -10...+10 V, 0(2)...+10 V

The AI825 Galvanic Isolated Analog Input Module has 4 individually galvanic

isolated channels. This module is suitable for applications requiring galvanic

isolated channels, and/or bipolar voltage or current inputs. Nominal input ranges

are: -20...+20 mA, 0(4)...+20 mA, -10...+10 V, 0(2)...+10 V.

The current input is able to handle a short circuit to the transmitter supply without

damage. The input withstand HART communication.

AI830/AI830A RTD Input Module

The AI830/AI830A Analog Input, RTD Module has 8 RTD (Pt100, Cu10, Ni100

and Ni120 and resistor) inputs. The inputs allow 3-wire connection to RTDs. Inputs

are monitored for open-circuit, short-circuit. Reference channel and internal supply

are also monitored.

AI835/AI835A Thermocouple/mV Input Module

The AI835/AI835A Analog Input, Thermocouple/mV Module has 8 differential

inputs for TC/mV measurements. One channel (channel 8) can be configured for

“Cold Junction” (ambient) temperature measurement, thus serving as the CJchannel

for the other channels on the module. All 8 channels can be used if no CJtemperature

measurement is needed. The inputs can be connected to a variety of

thermocouples with the following characteristics: B, C, E, J, K, N, R, S and T also

D, L and U for AI835A.

AI843 Thermocouple/mV Input Module, for Single or Redundant Applications

The AI843 Analog Input, Thermocouple/mV Module has 8 differential inputs for

TC/mV measurements. A separate channel is used for Cold Junction (ambient)

temperature measurement. The input can be connected to a variety of

thermocouples with the following characteristics: B, C, E, J, K, L, N, R, S, T and U.

AI845 Analog Input Module, for Single or Redundant Applications

The AI845 Analog Input Module has 8 analog inputs. Each channel can be either a

voltage or current input. The module has advanced on-board diagnostics and HART

pass-through functionality. It can be used in both single and redundant application.

Nominal input ranges are: 0(4)...+20mA, 0(1)...+5V.

AI880/AI880A High Integrity Analog Input Module for Single or Redundant Configuration

The AI880/AI880A High Integrity Analog Input Module is TÜV certified for

IEC 61508 SIL3, and EN 954-1 Category 4.

The AI880/AI880A has 8 analog inputs. The channels are for current input. The

module has advanced on-board diagnostics. It can be used in both single and

redundant configuration.

The AI880/AI880A complies with the NAMUR recommendation NE43, and

supports configurable over- and under range limits.

AI880A has support for HART pass-through communication. Nominal input range

is 0(4)...+20mA.

A0810/AO810V2 Analog Output Module, 0...20 mA

The AO810/AO810V2 Analog Output Module has 8 current outputs. State of

outputs can be set to a predetermined (OSP) value if a communication error is

detected. Nominal output range is: 0(4)... 20 mA.

AO815 Analog Output Module, 4...20 mA, HART

The AO815 Analog Output Module has 8 analog outputs. State of outputs can be set

to a predetermined (OSP) value if a communication error is detected. The module

has HART pass-through functionality. Nominal output range is 4...20 mA.

AO820 Bipolar Analog Output Module, -20 mA...+20 mA, -10 V...+10 V

The AO820 Bipolar Analog Output Module has 4 bipolar current or voltage outputs.

The choice of either current or voltage output is configurable per channel. Outputs

are individually galvanically isolated. State of outputs can be set to a predetermined

(OSP) value if a communication error is detected. Nominal output range are:

-20... +20 mA, 0(4)... +20 mA, -10... +10 V, 0(2)... +10 V.

AO845/AO845A Analog Output Module, for Single or Redundant Applications

The AO845/AO845A Analog Output Module has 8 analog outputs. State of outputs

can be set to a predetermined (OSP) value if a communication error is detected. The

module has advanced on-board diagnostics and HART pass-through functionality.

It can be used in both single and redundant applications. Nominal output range is:

4...20mA.

DI810 Digital Input Module, 24 V, Current Sinking

The DI810 Digital Input Module has 16 channels for 24 volt d.c. digital inputs.

The inputs are divided into two isolated groups of eight channels with a voltage

supervision input for each group. Each input channel provides current limiting,

EMC protection, input state LED indicator and optical isolation from the

ModuleBus.

DI811 Digital Input Module, 48 V, Current Sinking

The DI811 Digital Input Module has 16 channels for 48 volt d.c. digital inputs.

The inputs are divided into two isolated groups of eight channels with a voltage

supervision input for each group. Each input channel provides current limiting,

EMC protection, input state LED indicator and optical isolation from the

ModuleBus.

DI814 Digital Input Module, 24 V, Current Sourcing

The DI814 Digital Input Module has 16 channels for 24 volt d.c. current source

digital inputs. The inputs are divided into two isolated groups of eight channels with

a voltage supervision input for each group. Each input channel provides current

limiting, EMC protection, input state LED indicator and optical isolation from the

ModuleBus.

DI818 Digital Input Module, 24 V, Current Sinking

The DI818 Digital Input Module has 32 channels for 24 volt d.c. digital inputs. The

inputs are divided into two isolated groups of 16 channels with a voltage

supervision input for each group. Each input channel provides current limiting,

EMC protection, input state LED indicator and optical isolation from the

ModuleBus.

DI820 Digital Input Module, 120 V a.c./d.c.

The DI820 Digital Input Module has 8 channels for 120 volt a.c./d.c. digital inputs.

The inputs are individually isolated. Channel 1 can be used as voltage supervisor for

channels 2 - 4, and channel 8 can be used for channels 5 - 7. If voltage supervision is

disabled, channels 1 and 8 can be used as normal inputs. Each input channel

provides current limiting, EMC protection, input state LED indicator, noise filter

and optical isolation from the ModuleBus.

DI821 Digital Input Module, 230 V a.c./d.c.

The DI821 Digital Input Module has 8 channels for 230 volt a.c./d.c. digital inputs.

The inputs are individually isolated. Channel 1 can be used as voltage supervisor for

channels 2 - 4, and channel 8 can be used for channels 5 - 7. If voltage supervision is

disabled, channels 1 and 8 can be used as normal inputs. Each input channel

provides current limiting, EMC protection, input state LED indicator, noise filter

and optical isolation from the ModuleBus.

DI825 Digital Input Module, 125 V d.c. with SOE

The DI825 Digital Input Module had 8 channels for 125 V d.c. digital inputs and

sequence of events (SOE) handling capabilities. The sequence of events time stamp

has a resolution of 0.4 ms for each input channel. The inputs are individually

isolated. Channel 1 can be used as voltage supervisor for channels 2 - 4, and channel

8 can be used for channels 5 - 7. If voltage supervision is disabled, channels 1 and 8

can be used as normal inputs. Each input channel provides current limiting, EMC

protection, input state LED indicator, noise filter and optical isolation from the

ModuleBus.

DI828 Digital Input Module, 120 V a.c  d.c

The DI828 Digital Input Module has 16 channels for 120 volt a.c./d.c. digital inputs.

The inputs are individually isolated. Channel 1 can be used as voltage supervisor for

channels 2 - 8, and channel 16 can be used for channels 9 - 15. If voltage

supervision is disabled, channels 1 and 16 can be used as normal inputs. Each input

channel provides current limiting, EMC protection, input state LED indicator, noise

filter and optical isolation from the ModuleBus.

DI830 Digital Input Module, 24 V d.c. with SOE, Current Sinking

The DI830 Digital Input Module has 16 channels for 24 volt d.c. digital inputs and

sequence of events (SOE) handling capabilities. The sequence of events time stamp

has a resolution of 0.4 ms for each input channel. The inputs are divided into two

isolated groups of eight channels with a voltage supervision input for each group.

Each input channel provides current limiting, EMC protection, input state LED

indicator and optical isolation from the ModuleBus.

DI831 Digital Input Module, 48 V d.c. with SOE, Current Sinking

The DI831 Digital Input Module has 16 channels for 48 volt d.c. digital inputs and

sequence of events (SOE) handling capabilities. The sequence of events time stamp

has a resolution of 0.4 ms for each input channel. The inputs are divided into two

isolated groups of eight channels with a voltage supervision input for each group.

Each input channel provides current limiting, EMC protection, input state LED

indicator and optical isolation from the ModuleBus.

DI840 Digital Input Module, for Single or Redundant Applications

The DI840 Digital Input Module has 16 channels for 24 V d.c. digital inputs and

sequence of events (SOE) handling capabilities. The sequence of events time stamp

has a resolution of 1 ms for each input channel. Each input channel provides current

limiting, EMC protection, input state LED indicator and optical isolation from the

ModuleBus. The module has advanced on-board diagnostics. It can be used in both

single and redundant applications.

DI880 High Integrity Digital Input Module, for Single or Redundant Configuration

The DI880 High Integrity Digital Input Module is TÜV certified for

IEC 61508 SIL3 and EN 954-1 Category 4.

The DI880 has 16 channels for 24 V d.c. digital inputs and sequence of events

(SOE) handling capabilities. The sequence of events time stamp has a resolution of

1 ms for each input channel. Each input channel provides current limiting, EMC

protection, input state LED indicator and optical isolation from the ModuleBus.The

input voltage range is 18 to 30 V d.c. and the input current is 7 mA at 24 V d.c. The

module has advanced on-board diagnostics. It can be used in both single and

redundant configuration.

DI885 Digital Input Module, 24 V/48 V d.c. with SOE, Current Sinking

The DI885 Digital Input Module has 8 channels for 48 volt d.c. digital inputs with

or without open-circuit monitoring (wire break supervision), or 24 volt d.c.

electronic inputs without open-circuit monitoring; and sequence of events (SOE)

handling capabilities. The sequence of events time stamp has a resolution of 1 ms

for each input channel. The inputs are arranged in one group of 8 channels.

Each input channel provides current limiting, EMC protection, input state LED

indicator and optical isolation from the ModuleBus. The DI885 also has the

capability to monitor an internal or external sensor power supply (60 V d.c. max.).

DO810 Digital Output Module, 24 V, 0.5 A, Current Sourcing

The DO810 Digital Output Module has 16 channels for 24 volt d.c., 0.5 A, digital

outputs. The outputs are divided into two isolated groups of eight channels with a

voltage supervision input for each group. Each output channel provides protection

against short circuits to ground, over-voltage, over-temperature, EMC protection,

output state LED indicator and optical isolation from the ModuleBus. State of

outputs can be set to a predetermined (OSP) value if a communications lost error is

detected.

DO814 Digital Output Module, 24 V, 0.5 A

The DO814 Digital Output Module has 16 channels for 24 volt d.c., 0.5 A, current

sinking digital outputs. The outputs are divided into two isolated groups of eight

channels with a voltage supervision input for each group. Each output channel

provides protection against short circuits to power supply, over-temperature, EMC

protection, output state LED indicator and optical isolation from the ModuleBus.

State of outputs can be set to a predetermined (OSP) value if a communications lost

error is detected.

DO815 Digital Output Module, 24 V, 2 A, Current Sourcing

The DO815 Digital Output Module has 8 channels, 24 volt d.c., 2 A, digital outputs.

The outputs are divided into two isolated groups of four channels with a voltage

supervision input for each group. Each output channel provides protection against

short circuits to ground, over-temperature, EMC protection, output state LED

indicator and optical isolation from the ModuleBus. State of outputs can be set to a

predetermined (OSP) value if a communications lost error is detected.

DO818 Digital Output Module, 24 V, 0.5 A, Current Sinking

The DO818 Digital Output Module has 32 channels for 24 volt d.c., 0.5 A, digital

outputs. The outputs are divided into two isolated groups of 16 channels with a

voltage supervision input for each group. Each output channel provides protection

against short circuits to ground, over-voltage, over-temperature, EMC protection,

output state LED indicator and optical isolation from the ModuleBus. State of

outputs can be set to a predetermined (OSP) value if a communications lost error is

detected.

DO820 Digital Output Module, Relay Normally Open

The DO820 Digital Output Module has 8 channels for 230 volt a.c./d.c. relay

outputs. The outputs are individually isolated. Each output channel provides a relay

contact (NO - Normal Open), EMC protection, output state LED indicator and

optical isolation from the ModuleBus. State of outputs can be set to a predetermined

(OSP) value if a communications lost error is detected. Internal voltage is

supervised.

DO821 Digital Output Module, Relay Normally Closed

The DO821 Digital Output Module has 8 channels for 230 volt a.c./d.c. relay

outputs. The outputs are individually isolated. Each output channel provides a relay

contact (NC - Normal Closed), EMC protection, output state LED indicator and

optical isolation from the ModuleBus. State of outputs can be set to a predetermined

(OSP) value if a communications lost error is detected. Internal voltage is

supervised.

DO828 Digital Output Module, Relay Normally Open

The DO828 Digital Output Module has 16 channels for 250 AC / 125V DC relay

outputs. The outputs are individually isolated. Each output channel provides a relay

contact (NO - Normal Open), EMC protection, output state LED indicator and

optical isolation from the ModuleBus. State of outputs can be set to a predetermined

(OSP) value if a communications lost error is detected. Internal voltage is

supervised.

DO840 Digital Output Module, for Single or Redundant Applications

The DO840 Digital Output Module has 16 channels for 24 V d.c. The maximum

continuos output current is 0.5 A. The module has advanced on-board diagnostics. It

can be used in both single and redundant applications.

DO880 High Integrity Digital Output Module, for Single or Redundant Configuration

The DO880 High Integrity Digital Output Module is TÜV certified for

IEC 61508 SIL3 and EN 954-1 Category 4.

The DO880 has 16 channels for 24 V d.c. The maximum continuous output current

is 0.5 A. The module has advanced on-board diagnostics. It can be used in both

single and redundant configuration.

DP820 Incremental Pulse Counter Module

DP820 is an two-channel pulse counting module for incremental pulse transmitters

up to 1.5 MHz. Each channel contains counters and registers for position/length and

speed/frequency measurement. Each channel provides three balanced inputs for

connection of a pulse transmitter, one digital input and one digital output.

Pulse transmitters with RS422, +5 V, +12 V, +24 V and 13 mA interfaces can be

connected to DP820.

DP840 Incremental Pulse Counter Module, for Single or Redundant Applications

DP840 has 8 channels and each channel can be configured for pulse count or

frequency measurement. The maximum frequency of input signals is 20 kHz. The

inputs can also be read as digital input signals.

Input signal range NAMUR, 12 V and 24 V.

S800L I/O Modules

The I/O modules have open ventilated plastic enclosures and a bottom of sheet

metal. On the front of each I/O module there is one LED (STATUS) indicating the

module status and digital I/O modules have one status LED for each channel. Refer

to Hardware Indicators on page 47 for the status indication of the LEDs.

An electronic type designation ID in each module keeps the I/O module from being

taken into operation by the ModuleBus master, if a module’s ID doesn’t match the

configured module type definition.

Refer to specifications in Appendix A, Specifications for more information.

The module can be mounted on a standard DIN rail. The module is locked to the

DIN rail by using the locking screw.

The process connection is done via detachable connectors.

AI801 Analog Input Module, 0...20 mA

The AI801 Analog Input Module has 8 current inputs.

The current input is able to handle a short circuit to the transmitter supply without

damage. The input withstands HART communication.

Nominal input ranges are: 0(4)... +20 mA.

AO801 Analog Output Module, 0...20 mA

The AO801 Analog Output Module has 8 current outputs. State of outputs can be

set to a predetermined (OSP) value if a communications error is detected. Nominal

output range is: 0(4)... 20 mA.

DI801 Digital Input Module, 24 V, Current Sinking

The DI801 Digital Input Module has 16 channels for 24 volt d.c. digital inputs.

One input channel can be used for sensor voltage supervision. Each input channel

provides current limiting, EMC protection, input state LED indicator and optical

isolation from the ModuleBus.

DI802 Digital Input Module, 120 V a.c./d.c., Current Sinking

The DI802 Digital Input Module has 8 channels for 120 volt a.c./d.c. digital inputs.

Channel 8 can be used for sensor voltage supervision. Each input channel provides

current limiting, EMC protection, input state LED indicator and optical isolation

from the ModuleBus.

DI803 Digital Input Module, 230 V a.c./d.c., Current Sinking

The DI803 Digital Input Module has 8 channels for 230 volt a.c./d.c. digital inputs.

Channel 8 can be used for sensor voltage supervision. Each input channel provides

current limiting, EMC protection, input state LED indicator and optical isolation

from the ModuleBus.

DO801 Digital Output Module, 24 V, 0.5 V, Current Sinking

The DO801 Digital Output Module has 16 channels for 24 volt d.c., 0.5 A, digital

outputs. Each output channel provides protection against short circuits to ground,

over-voltage, over-temperature, EMC protection, output state LED indicator and

optical isolation from the ModuleBus. State of outputs can be set to a predetermined

(OSP) value if a communications lost error is detected.

DO802 Digital Output Module, 24-250 V, Relay Normally Open

The DO802 Digital Output Module has 8 channels for 24-250 volt d.c., digital

outputs. Each output channel provides protection against short circuits to ground,

over-voltage, over-temperature, EMC protection, output state LED indicator and

optical isolation from the ModuleBus. State of outputs can be set to a predetermined

(OSP) value if a communications lost error is detected.


  • ABB SCC-K Converter-Without Any Accessories Included Advance
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • ALSTOM BINARY INPUT BOARD 23BI61R1LF 1KWU300080 R1001E
  • ALSTOM LOCAL CONTROL PANEL DRWLM028-Q69-LCP-02S WITCH WIT AC120A
  • MOOG D136-002-005 MSC I and MSC II Motion Controllers D136002005
  • Honeywell CC-PAIX02 I/O Module Sizes High-level AI w/o HART - Differential
  • KEBA PI 050/A DC-link power supply PI050/B keplast i1000
  • WOODWARD 9907-1213 TM-25LP Single Coil Extend
  • GE GDS1168-FF-HCS-NF ALSTOM Power unit
  • GE control board GDS1168-SFP-HCS-NF (PIBE) PLX111909955 ALSTOM Power unit
  • GE IS400JPDMG1A PDM General Electric 28VDC
  • TMEIC (Toshiba-Mitsubishi)ARND-3119A Distributed control panel
  • ABB SCC-C Sample gas cooler 23070-0-103101100000
  • ABB 3BHE014557R0006 UNITROL1000-15 Controller drive unit
  • DS200TBQGG1ABB | GE Common Analog I/O Board
  • ABB 3BHE051589R0102 INU INTERFACE BOARD
  • GE Multilin C60-V03-HLH-F8L-H6DM6D-P6C-U6C-W6C Comprehensive Protection for Generators unit
  • GE Multilin G60G01HKHF8FH67M8FP6DU6D Comprehensive Protection for Generators unit
  • ABB SCC-F Sample gas cooler SCCF 23212-0-121210000000
  • GE Multilin F650BFBF1G0HIP feeder protection relay F650-B-F-B-F-1-G-0-HI-P
  • ABB Inspirational system HIEE300661R0001 UPC090AE01 ARCnet Coupler Card
  • Hirschmann MM20-Z6Z6Z6Z6SBHH Ethernet media module
  • Hirschmann MM20-Z6Z6Z6Z6SAHH Ethernet media module
  • ABB Detector 13CO2 10% URAS 14 analyzer AO2040 769137C
  • GE/CONVERTEAM ADVANCED MICRO CONTROLLER P111-6053
  • ABB 3BHE004573R0142 UFC760BE142 INU INTERFACE BOARD
  • ABB 3BHE002677R0095 NDBU-95 DDCS BRANCH UNIT
  • ABB 3BHE014023R0101 UFC789AE101 FSCD-BOARD,COATED
  • ABB 3AFE61320946P0001 LDMUI-01 Control motherboard
  • ABB NTAC-02 Pulse Encoder 58967441E
  • 3AFE61320954P0001 ABB 3AFE61320954 Control communication unit combination
  • Valmet metso CANMRG2 D202593L PCIe Embedded Industrial Controlle
  • Valmet metso PCIe Embedded Industrial Controller CAN MR G2 D202652L
  • GE EPSCPE115 RSTi-EP CPE115 Standalone Edge Controller (1.5MB user memory)
  • GE EPSCPE100 RSTi-EP CPE100 Standalone Edge Controller (1.0MB user memory)
  • ALSTOM GT13E2 KWZ6013880P0097 Control Panel
  • ALSTOM GT13E2 KWZ6031337P0281 Control Unit
  • ABB SDCS-IOB-3 DCS600 MultiDrive 3BSE004086R0001 unit
  • GE PACSystems™ RXi2-XP Industrial PC R2X0N1A0A01T0A
  • Automated MEx I/O Expander MEx816u
  • SIGMATEK Control Panel ETV0851 EDGE-Technology X86 compatible
  • GE 350-C-C-P5-S5-H-E-E-N-N-4E-D-N Intuitive and Innovative Feeder Protection
  • ABB REM543CG214AAAA Machine Terminals
  • ABB REM543CM216AAAA Machine Terminals
  • ABB NO measurement detector URAS 14 analyzer AO2040 768459H
  • ALSTOM 029.148972/02 RS-232 Serial port converter 029148972
  • LAMBDA ALPHA 400W TDK 24V/15V/7 Power supply unit
  • ALSTOM FZ1600R17KF6C-B2 IGBT Power Inverter Unit
  • ALSTOM PLB029-358908 Power Inverter Unit
  • ALSTOM CAN 4 X CAN EL CAN232.2 029356519 Four-channel serial communication unit
  • ALSTOM COP232.2 VME A32/D32 029.232446 ​ Programmable control unit
  • ALSTOM COP232.3 029.366.816 Programmable control unit COP2323
  • ABB Feeder protection and control REF601 and REJ601 BD446NN1XG
  • BASLER A404km-RT Industrial Camera
  • ABB REF615 HBFFAEAGNBA1ANB1XD Feeder Protection and Control
  • DMC-1040 Galil Motion control board
  • ABB 7625013-S ​INCLUDING PFSK113 BRUSH BLOCK
  • KUKA KCP2 00-130-547 robot teaching device Control unit
  • Vibro-Meter IOC8T 200-580-000-111 Input/Output Card
  • HUBNER FG40KK-8192G-90G-NG encoder
  • HUBNER FG40K-10000G-90G-NG encoder
  • YOKOGAWA AAI143-H00/K4A00 Analog Input Module
  • HIMA F3001020 Safety-Related Controller HIMatrix F30 010 03 F30 010 020
  • General Electric Ge IS200ESYSH1AAA Mark Vi Is200esysh1a Pcb Circuit Board
  • GE Speetronic MKVI IS200EXAMG1BAA dEX2100, H.S. Relay Driver Card
  • Bently Nevada 1701/25 Field Monitor, Seismic Input Monitor 2 Channel
  • honeywell SPS57101 I/O Module
  • GE IS210MVRFH1A ​ systems Counter, MARKVE, MVRF Module
  • Rockwell Automation 6181P-17A3MWX1DC Integrated Display Industrial Compute
  • NATIONAL INSTRUMENTS VXIPC-871B VXIpcTM 770/870B Series
  • WOODWARD 8440-2052 CONTROL unit
  • Embedded EPCPCRA embedded controller
  • AMAT 0041-48723 Controller instrument system
  • AMAT 0021-84842​ Controller instrument system
  • ICS TRIPLEX T8451 Trusted TMR Processor
  • ABB 1MRK002122-AB RED670 I/O-modules 670 series
  • ABB 1MRK002311-AA Protection Relay I/O control panel
  • YASKAWA AC SERVO MOTOR USAHEM-02-TE53
  • ABB DSPU131 3BSE000355R1 Module Terminal Unit
  • Siemens SIMATIC HMI TP700 6AV2124-0GC13-0AX0
  • TRICONEX 9566-850 Communication terminal block
  • vibro-meter IPC704 244-704-000-042,A2-B07-C232-D2.32-E2-F5000-G0-H0-I0 Aerospace detection equipment
  • Emerson SE4022 KJ3243X1-BK1 DeltaV Profibus DP module
  • AMAT 0010-23715 High-temperature probe
  • B&R 8MSA5X.RO-X400-1 SERVO MOTOR
  • Ametek Thermox 73938SE VERSION 3.55 MAIN IQ BOARD
  • GE IS200TCATH1ABA MKVIe control card
  • GE IS200EBACG2A - EX2100E BRDG AC FDBK, 650V
  • GE IS200JPDBG1A Mark* VIe I/O Leiterplatte
  • GE IS200EDISG1A Control circuit board
  • DALSA CR-GENO-M6400R3 camera with 16mm
  • Yokogawa YHC5150X HART Communicator
  • GE MIVII1000E00HI00 An economical choice for standard digital relaying applications
  • GE MIGIIQI55E00HI00 Digital Protection for Electrical Machines
  • DLQ144-PC-NB DEIF Illuminated marine bridge instrument
  • ABB 70BK08B 2VAA002001R0001 Bus coupler local bus Modbus RTU/TCP
  • 3500/94M VGADisplay Monito BENTLY 184826-01 120M8155-01
  • MEGGITT VM600 MPC4 machinery protection card MPC4 200-510-071-113 VIBRO-METER
  • ABB 1TGE120021R010 MLink​ Communication Gateway
  • ICS TRIPLEX T8111C Trusted TMR Processor
  • VESTAS CT318 VCS VCP MW Control Unit
  • TRACO POWER Industrial Power Supplies TIS600-128 115 / 230 VAC
  • AMAT 0010-32695 Controller instrument system
  • ELMO G-TUB30/480ERSS0 480VAC GOLD TUBA DIGITAL SERVO DRIVE
  • ELMO G-TUB30/480FEHSNA2 480VAC GOLD TUBA DIGITAL SERVO DRIVE
  • ELMO G-TUB30/230EESS0 30A/230VAC GOLD TUBA DIGITAL SERVO DRIVE
  • ABB SPCU1D50 Automatic voltage regulating module
  • ABB SPAU 341 C SPAU341C Voltage regulator
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • ABB CBI 22-P EX 3BDH000732R1 Binary Input CBI22PEX
  • ABB CTI 21-P Ex 3BDH000741R1 16/32 Inputs Ex, Temp. Input, SW Versio CTI21PEx
  • WOODWARD SPM-D10/YB Synchronizing Unit
  • AEROTECH UNIDEX100 MOTION CONTROLLER U100i
  • ROLLS-ROYCE PE9002 HELICON-X3 ETHERNET SWITCH U7
  • ABB 3BSE013175R1 GRBTU-01 PR:C Module Terminal Unit
  • ABB CT-APS.22 1SVR630180R3300 Analog I/I Signal Converter
  • Safemaster BN5930 Safety Relay
  • ABB 3BHE009017R0102 VLSCD Board XVC724BE102
  • ABB 3BHL000986P0006 controller UNIT FPX86-9377-A
  • MR627 P89627-0-2333400-300-401-601-701schneider ELAU Servo Drive
  • LDMTR-01 63940135F ABB Inverter Contro
  • ABB CHBX01R 2VAA008575R1 BASE MODUL
  • ABB CHBX01L 2VAA008574R1 BASE MODUL
  • ABB RMU610 2VAA008425R1 BASE MODUL
  • ABB 3BUS208796-501 Controller unit
  • ABB HIEE205014R1 HI220856-312/20 UNC4673AV1 Analog Measuring Card
  • ABB P8151B TMR Analog Input unit
  • ABB P8403 TMR Analog Inpu