Energy and Environmental
WhatsApp :+86-18144100983
NameDescriptionContent
  • Products related to categories: servo, frequency conversion, HMI, driver, distributed DCS, IPC (PC bus industrial computer), PLC (programmable control system), DCS (distributed control system), FCS (field bus system), robot and other products and technical services.
  • Applications: Wind energy, automobile, ship, transportation, manufacturing, aviation, petroleum, natural gas, thermal power, thermal power, nuclear energy, steel, metallurgy, mining, power and other industries
  • Controller PLC\Robot servo drive Electro-hydraulic servo valve\DCS system/Distributed control systemSystem rack\Communication adapter\Analog output\Analog input\
  • \Multi-meter energy meter\Ignition\circuit board\Crimp terminal\Electric ac drive\Low voltage DC power module\Electro-hydraulic\servo valve\Automatic control system\exchange\Network communication module
    controller\Processor module\dynamo\Electric machine\Servo drive\Touch screen\Input/output module\Water treatment monitoring system\Automobile\manufacturing system\Thermoelectric control system\
  • Digital output\Digital input\Mechanical protection system\High speed CPU
  • Electric power system\Chemical testing system\Petroleum control system\Tension monitoring system
  • DCS Distributed\control system\Steel control system\Steam\turbine system\Power generation system\
  • Thermal power generation system\Wind power system\Medium and high voltage frequency\conversion system\Precision motion system\Programmable control system\

E-mail

Password

Register Forgot password?
  • Singapore New Energy Corporation
  • Geylang Bahru Industrial Estate
  • การทางหลวงแห่งประเทศไทย
  • American Petroleum Group
  • Indian shipping works
  • Pakistan Gas Company
  • Russian Automotive Industry Corporation
  • Brazilian Mining Company
  • Bangladesh Hydro power Plant
  • Egyptian Iron and Steel Manufacturing Co
  • Groupe d’exploitation du métro français
  • Für meinen vater
  • BYD
  • Mongolia Wind Farm
  • Empresa venezolana de procesamiento de petróleo
  • alibaba
  • Sichuan Huayingshan Power Plant
  • Huadian Datong Power Plant
  • Guodian Shuangyashan Power Generation Co., Ltd.
  • Baosteel Group Xinjiang Bayi Steel Co., Ltd.
  • Guodian Changzhou Power Plant
  • Xingtai Iron and Steel Co., Ltd.
  • Guodian Fee County Power Generation Co., Ltd.
  • Yangzhou Second Power Plant
  • Sichuan Jintang Power Plant
  • Xingcheng Special Steel Co., Ltd.
  • Quzhou Yuanli Metal Products Co., Ltd.
  • Zijin Mining Group
  • (Bangladesh) Metro Construction Company
  • WuHan steel co., ltd.
  • MaAnShan  steel co., ltd.

ABB S800 I/O Modules and Termination Units

From:ABB | author:kongjiang | Release :2025-08-30 | 2441 view: | Share:

ABB S800 I/O Modules and Termination Units 

The S800 I/O is distributed as modular I/O that communicates with numerous

controllers over Advant Fieldbus 100 (AF100), PROFIBUS-DP, or directly.

The S800 I/O provides easy installation of the I/O modules and process cabling.

It is highly modularized and flexible so that I/O modules can be combined to suit

many applications. The S800 I/O can be mounted in many configurations to fit most

requirements.

The S800 I/O provides easy installation of the I/O modules and process cabling.

It is highly modularized and flexible so that the I/O modules can be combined to suit

many applications, including most types of signals, HART and Intrinsic Safety

Interface. The S800 I/O modules and a Fieldbus Communication Interface (FCI) are

combined to form an I/O Station. The S800 I/O can be used in both single and

redundant applications.

In general, all S800 units are G3 compliant. G3 compliant modules withstand more

severe environmental conditions according to ISA-S71.04. The following S800

units are G2 compliant - SD821, SD822, SD823, SD831, SD832, SD833, SD834,

SS822, SS832, TB811 and CI830. G3 compliant versions of SD822 and SS822 are

also available (refer to SD822Z and SS822Z).

All modules are marked with a bar code that shows the serial number, article ID and

the product revision number. A separate bar code strip is also enclosed along with

the module for placing on the module, if needed. The bar code is of type

Bar-code 128.

For more information, refer to S800 I/O Getting Started(3BSE020923*) manual.

The S800 I/O can be categorized into:

•Module Termination Units (MTU)

•I/O modules – S800 I/O modules and S800L I/O modules.

S800 I/O modules are designed to be used together with a Module Termination

Unit.

S800L I/O modules are designed to be directly mounted on a standard DIN rail.

The module also contains terminals for connections.

Module Termination Units and Terminal Units

The Module Termination Units (MTU) are passive base units used to house the I/O

modules. They contain the process wiring terminals and a section of the

ModuleBus.

The Module Termination Units (MTU) distributes the ModuleBus to the I/O module

and to the next MTU. It also generates the correct address to the I/O module by

shifting the outgoing position signals to the next MTU.

Two mechanical keys are used to configure the MTU for different types of I/O

modules. This is only a mechanical configuration and it does not affect the

functionality of the MTU or the I/O module. Each key has six positions, which gives

a total number of 36 different configurations. The configuration can be changed

with a screwdriver.

The MTU can be mounted on a standard DIN rail. It has a mechanical latch that

locks the MTU to the DIN rail. The latch can be released with a screwdriver.

The MTU has a mechanical locking mechanism that locks the module in its

position. This mechanism also gives the signal BLOCK to the I/O module that

keeps the module in its init state until it is locked in its position.

The top part of the MTU can be removed to replace the termination board even with

the system running. Such a need can be caused by a damaged terminal screw.

The MTUs are available in tree versions (Compact, Extended and Redundant).

The Compact MTU version typically provides for a compact installation of the I/O

modules using 1 wire connections.

TU805 Terminal Unit for 50 Volt Applications

The TU805 is a 16 channel terminal unit. Used to enable 2- and 3-wire connections

on DI801 or DO801. The Terminal Unit is mounted direct on DI801 or DO801.

TU810/TU810V1 Compact MTU for 50 Volt Applications

The TU810 is a 16 channel compact module termination unit. The TU810 has three

rows of terminals for field signals and process power connections.

TU811/TU811V1 Compact MTU for 250 Volt Applications

The TU811 is a 8 channel compact module termination unit. The TU811 has three

rows of terminals for field signals and process power connection.

TU812/TU812V1 Compact MTU for 50 Volt Applications and 25 pin D-sub for Process Connections

The TU812 is a 16 channel compact module termination unit. The TU812 has a 25

pin D-Sub connector for field signals and process power connections.

TU813 Compact MTU for 250 V Applications

The TU813 is a 8 channel compact module termination unit. The TU813 has three

rows of crimp snap-in connectors for field signals and process power connections.

TU814/TU814V1 Compact MTU for 50 Volt Applications The TU814 is a 16 channel compact module termination unit. The TU814 has three

rows of crimp snap-in connectors for field signals and process power connections.

TU818 Compact MTU for 50 Volt Applications

The TU818 is a 32 channel compact module termination unit. It consists of 40 pole

screw-terminals for process connections.

TU819 Compact MTU for 50 Volt Applications

The TU819 is a 32 channel compact module termination unit. It consists of two

D-sub 25 pole connector for field signals and process power connections, which

enables connection to the Phoenix Varioface, ABB interfast and so on.

TU830/TU830V1 Extended MTU for 50 Volt Applications The TU830 is a 16 channel extended module termination unit. The TU830 has three

rows of terminals for field signals and process power connection.

TU831/TU831V1 Extended MTU for 250 Volt Applications The TU831 is a 8 channel extended module termination unit. TU831 has two rows

of terminals for field signals and process power connection.

TU833 Extended MTU for 50 Volt Applications

The TU833 is a 16 channel extended module termination unit. The TU833 has three

rows of spring-case terminals for field signals and process power connection.

TU834 Extended MTU for 50 Volt Applications

The TU834 is a 8 channel extended module termination unit. The MTU has two

rows of terminals for field signals and process power connection. The MTU has

place for 8 replaceable shunt sticks (i.e one shunt stick per channel) for conversion

of the input current signal to a voltage signal.

TU835/TU835V1 Extended MTU, Individually Fused per Channel for 50 Volt Applications

The TU835 is a 8 channel extended module termination unit. The TU835 has two

rows of terminals for process power connection and a single row of field signal

connections. Each channel has one fused (3 A max.) transmitter power outlet

terminal and one signal terminal. Process voltage can be connected to 2 individually

isolated groups.

TU836/TU836V1 Extended MTU, Individually Fused per Channel for 250 Volt Applications

The TU836 is a 8 channel extended module termination unit. The TU836 has two

rows of terminals for field signals and process power connection. Each channel has

one fused (3 A max.) power outlet terminal and one signal return terminal. Process

voltage can be connected to 2 individually isolated groups.

TU837/TU837V1 Extended MTU, Individually Fused per Channel for 250 Volt Applications The TU837 is a 8 channel extended module termination unit. The TU837 has two

rows of terminals for field signals and process power connection. Each channel has

one fused (3 A max.) power outlet terminal and two signal terminals. Process

voltage return can be connected to two individually isolated groups.

TU838 Extended MTU, Individually Fused per Channel for 50 Volt Applications The TU838 is a 16 channel extended module termination unit. The TU838 has two

rows of terminals for field signals and process power connection. Each channel has

one fused (3 A max.) transmitter power outlet terminal and one signal terminal.

Process voltage can be connected to two individually isolated groups.

TU839 Extended MTU for 250 Volt Applications

The TU839 is a 8 channel extended module termination unit. TU839 has two rows

of terminals for field signals and process power connection. Each channel has one

sensor power outlet terminal and two signal terminals. Process voltage can be

connected to two individually isolated groups

TU842 Redundant Horizontal MTU for 50 V Applications

The TU842 is a 16 channel redundant module termination unit. The TU842 has

three rows of terminals for field signals and process power connection.It is intended

for mounting on a horizontal DIN rail. There is space on the MTU for two I/O

modules connected to separate ModuleBuses.

TU843 Redundant Vertical MTU for 50 V Applications

The TU843 is a 16 channel redundant module termination unit. The TU843 has

three rows of terminals for field signals and process power connection. It is intended

for mounting on a vertical DIN rail. There is space on the MTU for two I/O modules

connected to separate ModuleBuses.

TU844 Redundant Horizontal MTU for 50 V Applications

The TU844 is a 8 channel redundant module termination unit. The TU844 has two

rows of terminals for field signals and process power connection. It is a intended for

mounting on a horizontal DIN rail. The MTU has place for 8 replaceable shunt

sticks (i.e one shunt stick per channel) for conversion of the input current signal to a

voltage signal. There is space on the MTU for two I/O modules connected to

separate ModuleBuses.

TU845 Redundant Vertical MTU for 50 V Applications

The TU845 is a 8 channel redundant module termination unit. The TU845 has three

rows of terminals for field signals and process power connection. It is intended for

mounting on a vertical DIN rail. The MTU has place for 8 replaceable shunt sticks

(i.e one shunt stick per channel) for conversion of the input current signal to a

voltage signal. There is space on the MTU for two I/O modules connected to

separate ModuleBuses.

TU850 Extended MTU, Individually Current Limited and Disconnectable per Channel for 50 V Applications

The TU850 is a 16 channel extended module termination unit. TU850 has two rows

of terminals for field signals and process power connection. Each channel has one

current limited sensor/transmitter power outlet terminal and one signal terminal.

Process voltage can be connected to two individually isolated groups.

TU851 Extended MTU for 250 Volt Applications

The TU851 250V Extended MTU Which allows a maximum of 16 isolated I/O

channels and process voltage connections. It has a 32 pole screw-terminal for

process connections.

TU852 Redundant Horizontal MTU for 50 V Applications

The TU852 is a redundant module termination unit for up to 16 channels. The

TU852 has a two 25 pin D-Sub connector for field signals and process power

connections. It is a intended for mounting on a horizontal DIN rail. There is space

on the MTU for two I/O modules connected to separate Modulebuses.

TU854 Redundant Horizontal MTU for 50 V Applications

he TU854 is a 8 channel redundant module termination unit. The TU854 has a 25

pin D-Sub connector for field signals and process power connections. It is a

intended for mounting on a horizontal DIN rail. The MTU has place for 8

replaceable shunt sticks (i.e one shunt stick per channel) for conversion of the input

current signal to a voltage signal. There is space on the MTU for two I/O modules

connected to separate ModuleBuses.

TY801 Shunt Stick

The TY801 is a shunt stick for current or voltage signals together with AI845 or

AI880 and TU844 or TU845.

TY804 Shunt Stick

The TY804 is a shunt stick for NAMUR signals together with DP840 and TU844 or

TU845.

TY820 Temperature Sensor

The TY820 can be used with AI835/AI835A and AI843 to measure cold junction

temperature.

S800 I/O Modules

The I/O modules have open ventilated plastic enclosures. On the front of all I/O

modules there are at least three LEDs (FAULT, RUN and WARNING) indicating

the module status. Additionally some modules have LEDs indicating OSP or

PRIMARY, see Table 3 and Table 4.

I/O modules may be replaced in a fully operational I/O station. Mechanical keying

on modules and MTUs protect I/O modules from being inserted in positions where

they could be damaged by excessive voltage or current. An electronic type

designation ID in each module keeps the I/O module from being taken into

operation by the ModuleBus master, if a module’s ID doesn’t match the configured

module type definition. There are modules for both single and redundant

applications.

Refer to specifications in Appendix A, Specifications for more information.

AI810 Analog Input Module, 0...20 mA, 0...10 V

The AI810 Analog Input Module has 8 current and voltage inputs. The inputs are

independent for each channel, in that either voltage or current can be measured.

The current input is able to handle a short circuit to the transmitter supply without

damage. The input withstand HART communication.

Nominal input ranges are: 0(4)... +20 mA, 0(2)... +10 V.

AI815 Analog Input Module, 0..20mA, 0..5V, HART

The AI815 Analog Input Module has 8 analog inputs. The inputs can be configured

for voltage or current.

The module has HART pass-through functionality.

Nominal input ranges are: 0(4)...+20 mA, 0(1)...+5 V.

AI820 Differential Analog Input Module, +/- 20 mA, +/- 10 V, +/- 5 V

The AI820 Differential Analog Input Module has 4 differential, bipolar

current/voltage inputs. This module is suitable for applications requiring high

common mode rejection ratings, and/or bipolar voltage or current inputs. Nominal

input ranges are: -20...+20 mA, 0(4)...+20 mA, -10...+10 V, 0(2)...+10 V,

-5...+5 V and 0(1)...+5 V.

The current input is able to handle a short circuit to the transmitter supply without

damage. The input withstand HART communication.

AI825 Galvanic Isolated Analog Input Module, -20...+20 mA, 0(4)...+20 mA, -10...+10 V, 0(2)...+10 V

The AI825 Galvanic Isolated Analog Input Module has 4 individually galvanic

isolated channels. This module is suitable for applications requiring galvanic

isolated channels, and/or bipolar voltage or current inputs. Nominal input ranges

are: -20...+20 mA, 0(4)...+20 mA, -10...+10 V, 0(2)...+10 V.

The current input is able to handle a short circuit to the transmitter supply without

damage. The input withstand HART communication.

AI830/AI830A RTD Input Module

The AI830/AI830A Analog Input, RTD Module has 8 RTD (Pt100, Cu10, Ni100

and Ni120 and resistor) inputs. The inputs allow 3-wire connection to RTDs. Inputs

are monitored for open-circuit, short-circuit. Reference channel and internal supply

are also monitored.

AI835/AI835A Thermocouple/mV Input Module

The AI835/AI835A Analog Input, Thermocouple/mV Module has 8 differential

inputs for TC/mV measurements. One channel (channel 8) can be configured for

“Cold Junction” (ambient) temperature measurement, thus serving as the CJchannel

for the other channels on the module. All 8 channels can be used if no CJtemperature

measurement is needed. The inputs can be connected to a variety of

thermocouples with the following characteristics: B, C, E, J, K, N, R, S and T also

D, L and U for AI835A.

AI843 Thermocouple/mV Input Module, for Single or Redundant Applications

The AI843 Analog Input, Thermocouple/mV Module has 8 differential inputs for

TC/mV measurements. A separate channel is used for Cold Junction (ambient)

temperature measurement. The input can be connected to a variety of

thermocouples with the following characteristics: B, C, E, J, K, L, N, R, S, T and U.

AI845 Analog Input Module, for Single or Redundant Applications

The AI845 Analog Input Module has 8 analog inputs. Each channel can be either a

voltage or current input. The module has advanced on-board diagnostics and HART

pass-through functionality. It can be used in both single and redundant application.

Nominal input ranges are: 0(4)...+20mA, 0(1)...+5V.

AI880/AI880A High Integrity Analog Input Module for Single or Redundant Configuration

The AI880/AI880A High Integrity Analog Input Module is TÜV certified for

IEC 61508 SIL3, and EN 954-1 Category 4.

The AI880/AI880A has 8 analog inputs. The channels are for current input. The

module has advanced on-board diagnostics. It can be used in both single and

redundant configuration.

The AI880/AI880A complies with the NAMUR recommendation NE43, and

supports configurable over- and under range limits.

AI880A has support for HART pass-through communication. Nominal input range

is 0(4)...+20mA.

A0810/AO810V2 Analog Output Module, 0...20 mA

The AO810/AO810V2 Analog Output Module has 8 current outputs. State of

outputs can be set to a predetermined (OSP) value if a communication error is

detected. Nominal output range is: 0(4)... 20 mA.

AO815 Analog Output Module, 4...20 mA, HART

The AO815 Analog Output Module has 8 analog outputs. State of outputs can be set

to a predetermined (OSP) value if a communication error is detected. The module

has HART pass-through functionality. Nominal output range is 4...20 mA.

AO820 Bipolar Analog Output Module, -20 mA...+20 mA, -10 V...+10 V

The AO820 Bipolar Analog Output Module has 4 bipolar current or voltage outputs.

The choice of either current or voltage output is configurable per channel. Outputs

are individually galvanically isolated. State of outputs can be set to a predetermined

(OSP) value if a communication error is detected. Nominal output range are:

-20... +20 mA, 0(4)... +20 mA, -10... +10 V, 0(2)... +10 V.

AO845/AO845A Analog Output Module, for Single or Redundant Applications

The AO845/AO845A Analog Output Module has 8 analog outputs. State of outputs

can be set to a predetermined (OSP) value if a communication error is detected. The

module has advanced on-board diagnostics and HART pass-through functionality.

It can be used in both single and redundant applications. Nominal output range is:

4...20mA.

DI810 Digital Input Module, 24 V, Current Sinking

The DI810 Digital Input Module has 16 channels for 24 volt d.c. digital inputs.

The inputs are divided into two isolated groups of eight channels with a voltage

supervision input for each group. Each input channel provides current limiting,

EMC protection, input state LED indicator and optical isolation from the

ModuleBus.

DI811 Digital Input Module, 48 V, Current Sinking

The DI811 Digital Input Module has 16 channels for 48 volt d.c. digital inputs.

The inputs are divided into two isolated groups of eight channels with a voltage

supervision input for each group. Each input channel provides current limiting,

EMC protection, input state LED indicator and optical isolation from the

ModuleBus.

DI814 Digital Input Module, 24 V, Current Sourcing

The DI814 Digital Input Module has 16 channels for 24 volt d.c. current source

digital inputs. The inputs are divided into two isolated groups of eight channels with

a voltage supervision input for each group. Each input channel provides current

limiting, EMC protection, input state LED indicator and optical isolation from the

ModuleBus.

DI818 Digital Input Module, 24 V, Current Sinking

The DI818 Digital Input Module has 32 channels for 24 volt d.c. digital inputs. The

inputs are divided into two isolated groups of 16 channels with a voltage

supervision input for each group. Each input channel provides current limiting,

EMC protection, input state LED indicator and optical isolation from the

ModuleBus.

DI820 Digital Input Module, 120 V a.c./d.c.

The DI820 Digital Input Module has 8 channels for 120 volt a.c./d.c. digital inputs.

The inputs are individually isolated. Channel 1 can be used as voltage supervisor for

channels 2 - 4, and channel 8 can be used for channels 5 - 7. If voltage supervision is

disabled, channels 1 and 8 can be used as normal inputs. Each input channel

provides current limiting, EMC protection, input state LED indicator, noise filter

and optical isolation from the ModuleBus.

DI821 Digital Input Module, 230 V a.c./d.c.

The DI821 Digital Input Module has 8 channels for 230 volt a.c./d.c. digital inputs.

The inputs are individually isolated. Channel 1 can be used as voltage supervisor for

channels 2 - 4, and channel 8 can be used for channels 5 - 7. If voltage supervision is

disabled, channels 1 and 8 can be used as normal inputs. Each input channel

provides current limiting, EMC protection, input state LED indicator, noise filter

and optical isolation from the ModuleBus.

DI825 Digital Input Module, 125 V d.c. with SOE

The DI825 Digital Input Module had 8 channels for 125 V d.c. digital inputs and

sequence of events (SOE) handling capabilities. The sequence of events time stamp

has a resolution of 0.4 ms for each input channel. The inputs are individually

isolated. Channel 1 can be used as voltage supervisor for channels 2 - 4, and channel

8 can be used for channels 5 - 7. If voltage supervision is disabled, channels 1 and 8

can be used as normal inputs. Each input channel provides current limiting, EMC

protection, input state LED indicator, noise filter and optical isolation from the

ModuleBus.

DI828 Digital Input Module, 120 V a.c  d.c

The DI828 Digital Input Module has 16 channels for 120 volt a.c./d.c. digital inputs.

The inputs are individually isolated. Channel 1 can be used as voltage supervisor for

channels 2 - 8, and channel 16 can be used for channels 9 - 15. If voltage

supervision is disabled, channels 1 and 16 can be used as normal inputs. Each input

channel provides current limiting, EMC protection, input state LED indicator, noise

filter and optical isolation from the ModuleBus.

DI830 Digital Input Module, 24 V d.c. with SOE, Current Sinking

The DI830 Digital Input Module has 16 channels for 24 volt d.c. digital inputs and

sequence of events (SOE) handling capabilities. The sequence of events time stamp

has a resolution of 0.4 ms for each input channel. The inputs are divided into two

isolated groups of eight channels with a voltage supervision input for each group.

Each input channel provides current limiting, EMC protection, input state LED

indicator and optical isolation from the ModuleBus.

DI831 Digital Input Module, 48 V d.c. with SOE, Current Sinking

The DI831 Digital Input Module has 16 channels for 48 volt d.c. digital inputs and

sequence of events (SOE) handling capabilities. The sequence of events time stamp

has a resolution of 0.4 ms for each input channel. The inputs are divided into two

isolated groups of eight channels with a voltage supervision input for each group.

Each input channel provides current limiting, EMC protection, input state LED

indicator and optical isolation from the ModuleBus.

DI840 Digital Input Module, for Single or Redundant Applications

The DI840 Digital Input Module has 16 channels for 24 V d.c. digital inputs and

sequence of events (SOE) handling capabilities. The sequence of events time stamp

has a resolution of 1 ms for each input channel. Each input channel provides current

limiting, EMC protection, input state LED indicator and optical isolation from the

ModuleBus. The module has advanced on-board diagnostics. It can be used in both

single and redundant applications.

DI880 High Integrity Digital Input Module, for Single or Redundant Configuration

The DI880 High Integrity Digital Input Module is TÜV certified for

IEC 61508 SIL3 and EN 954-1 Category 4.

The DI880 has 16 channels for 24 V d.c. digital inputs and sequence of events

(SOE) handling capabilities. The sequence of events time stamp has a resolution of

1 ms for each input channel. Each input channel provides current limiting, EMC

protection, input state LED indicator and optical isolation from the ModuleBus.The

input voltage range is 18 to 30 V d.c. and the input current is 7 mA at 24 V d.c. The

module has advanced on-board diagnostics. It can be used in both single and

redundant configuration.

DI885 Digital Input Module, 24 V/48 V d.c. with SOE, Current Sinking

The DI885 Digital Input Module has 8 channels for 48 volt d.c. digital inputs with

or without open-circuit monitoring (wire break supervision), or 24 volt d.c.

electronic inputs without open-circuit monitoring; and sequence of events (SOE)

handling capabilities. The sequence of events time stamp has a resolution of 1 ms

for each input channel. The inputs are arranged in one group of 8 channels.

Each input channel provides current limiting, EMC protection, input state LED

indicator and optical isolation from the ModuleBus. The DI885 also has the

capability to monitor an internal or external sensor power supply (60 V d.c. max.).

DO810 Digital Output Module, 24 V, 0.5 A, Current Sourcing

The DO810 Digital Output Module has 16 channels for 24 volt d.c., 0.5 A, digital

outputs. The outputs are divided into two isolated groups of eight channels with a

voltage supervision input for each group. Each output channel provides protection

against short circuits to ground, over-voltage, over-temperature, EMC protection,

output state LED indicator and optical isolation from the ModuleBus. State of

outputs can be set to a predetermined (OSP) value if a communications lost error is

detected.

DO814 Digital Output Module, 24 V, 0.5 A

The DO814 Digital Output Module has 16 channels for 24 volt d.c., 0.5 A, current

sinking digital outputs. The outputs are divided into two isolated groups of eight

channels with a voltage supervision input for each group. Each output channel

provides protection against short circuits to power supply, over-temperature, EMC

protection, output state LED indicator and optical isolation from the ModuleBus.

State of outputs can be set to a predetermined (OSP) value if a communications lost

error is detected.

DO815 Digital Output Module, 24 V, 2 A, Current Sourcing

The DO815 Digital Output Module has 8 channels, 24 volt d.c., 2 A, digital outputs.

The outputs are divided into two isolated groups of four channels with a voltage

supervision input for each group. Each output channel provides protection against

short circuits to ground, over-temperature, EMC protection, output state LED

indicator and optical isolation from the ModuleBus. State of outputs can be set to a

predetermined (OSP) value if a communications lost error is detected.

DO818 Digital Output Module, 24 V, 0.5 A, Current Sinking

The DO818 Digital Output Module has 32 channels for 24 volt d.c., 0.5 A, digital

outputs. The outputs are divided into two isolated groups of 16 channels with a

voltage supervision input for each group. Each output channel provides protection

against short circuits to ground, over-voltage, over-temperature, EMC protection,

output state LED indicator and optical isolation from the ModuleBus. State of

outputs can be set to a predetermined (OSP) value if a communications lost error is

detected.

DO820 Digital Output Module, Relay Normally Open

The DO820 Digital Output Module has 8 channels for 230 volt a.c./d.c. relay

outputs. The outputs are individually isolated. Each output channel provides a relay

contact (NO - Normal Open), EMC protection, output state LED indicator and

optical isolation from the ModuleBus. State of outputs can be set to a predetermined

(OSP) value if a communications lost error is detected. Internal voltage is

supervised.

DO821 Digital Output Module, Relay Normally Closed

The DO821 Digital Output Module has 8 channels for 230 volt a.c./d.c. relay

outputs. The outputs are individually isolated. Each output channel provides a relay

contact (NC - Normal Closed), EMC protection, output state LED indicator and

optical isolation from the ModuleBus. State of outputs can be set to a predetermined

(OSP) value if a communications lost error is detected. Internal voltage is

supervised.

DO828 Digital Output Module, Relay Normally Open

The DO828 Digital Output Module has 16 channels for 250 AC / 125V DC relay

outputs. The outputs are individually isolated. Each output channel provides a relay

contact (NO - Normal Open), EMC protection, output state LED indicator and

optical isolation from the ModuleBus. State of outputs can be set to a predetermined

(OSP) value if a communications lost error is detected. Internal voltage is

supervised.

DO840 Digital Output Module, for Single or Redundant Applications

The DO840 Digital Output Module has 16 channels for 24 V d.c. The maximum

continuos output current is 0.5 A. The module has advanced on-board diagnostics. It

can be used in both single and redundant applications.

DO880 High Integrity Digital Output Module, for Single or Redundant Configuration

The DO880 High Integrity Digital Output Module is TÜV certified for

IEC 61508 SIL3 and EN 954-1 Category 4.

The DO880 has 16 channels for 24 V d.c. The maximum continuous output current

is 0.5 A. The module has advanced on-board diagnostics. It can be used in both

single and redundant configuration.

DP820 Incremental Pulse Counter Module

DP820 is an two-channel pulse counting module for incremental pulse transmitters

up to 1.5 MHz. Each channel contains counters and registers for position/length and

speed/frequency measurement. Each channel provides three balanced inputs for

connection of a pulse transmitter, one digital input and one digital output.

Pulse transmitters with RS422, +5 V, +12 V, +24 V and 13 mA interfaces can be

connected to DP820.

DP840 Incremental Pulse Counter Module, for Single or Redundant Applications

DP840 has 8 channels and each channel can be configured for pulse count or

frequency measurement. The maximum frequency of input signals is 20 kHz. The

inputs can also be read as digital input signals.

Input signal range NAMUR, 12 V and 24 V.

S800L I/O Modules

The I/O modules have open ventilated plastic enclosures and a bottom of sheet

metal. On the front of each I/O module there is one LED (STATUS) indicating the

module status and digital I/O modules have one status LED for each channel. Refer

to Hardware Indicators on page 47 for the status indication of the LEDs.

An electronic type designation ID in each module keeps the I/O module from being

taken into operation by the ModuleBus master, if a module’s ID doesn’t match the

configured module type definition.

Refer to specifications in Appendix A, Specifications for more information.

The module can be mounted on a standard DIN rail. The module is locked to the

DIN rail by using the locking screw.

The process connection is done via detachable connectors.

AI801 Analog Input Module, 0...20 mA

The AI801 Analog Input Module has 8 current inputs.

The current input is able to handle a short circuit to the transmitter supply without

damage. The input withstands HART communication.

Nominal input ranges are: 0(4)... +20 mA.

AO801 Analog Output Module, 0...20 mA

The AO801 Analog Output Module has 8 current outputs. State of outputs can be

set to a predetermined (OSP) value if a communications error is detected. Nominal

output range is: 0(4)... 20 mA.

DI801 Digital Input Module, 24 V, Current Sinking

The DI801 Digital Input Module has 16 channels for 24 volt d.c. digital inputs.

One input channel can be used for sensor voltage supervision. Each input channel

provides current limiting, EMC protection, input state LED indicator and optical

isolation from the ModuleBus.

DI802 Digital Input Module, 120 V a.c./d.c., Current Sinking

The DI802 Digital Input Module has 8 channels for 120 volt a.c./d.c. digital inputs.

Channel 8 can be used for sensor voltage supervision. Each input channel provides

current limiting, EMC protection, input state LED indicator and optical isolation

from the ModuleBus.

DI803 Digital Input Module, 230 V a.c./d.c., Current Sinking

The DI803 Digital Input Module has 8 channels for 230 volt a.c./d.c. digital inputs.

Channel 8 can be used for sensor voltage supervision. Each input channel provides

current limiting, EMC protection, input state LED indicator and optical isolation

from the ModuleBus.

DO801 Digital Output Module, 24 V, 0.5 V, Current Sinking

The DO801 Digital Output Module has 16 channels for 24 volt d.c., 0.5 A, digital

outputs. Each output channel provides protection against short circuits to ground,

over-voltage, over-temperature, EMC protection, output state LED indicator and

optical isolation from the ModuleBus. State of outputs can be set to a predetermined

(OSP) value if a communications lost error is detected.

DO802 Digital Output Module, 24-250 V, Relay Normally Open

The DO802 Digital Output Module has 8 channels for 24-250 volt d.c., digital

outputs. Each output channel provides protection against short circuits to ground,

over-voltage, over-temperature, EMC protection, output state LED indicator and

optical isolation from the ModuleBus. State of outputs can be set to a predetermined

(OSP) value if a communications lost error is detected.


  • ABB 500PSM03 1MRB150038 Power Supply module
  • Valmet metso D201563L Control unit accessories
  • ​Valmet metso D201473L AII8 Control unit accessories
  • EATON XVS-430-10MPI-1-10 Touch panel 24 V DC TFTcolor, ethernet, RS232
  • bently 60M100-00 Condition Monitoring System
  • ABB 3BHB004791R0101 IGCT Gate Power Supply Unit
  • ABB TAS.580.0550.G00 HARDWARE BOARD ABB100 COMPONENTS SIDE
  • ABB SYN5201A-Z,V277 3BHB006714R0277 Automatic single-channel synchronization unit
  • ABB SUE3000 1VCF750090R0804 Operation screen unit 1VCR007346
  • ABB SENSYCAL FCU400-IR Product Summary
  • ABB SDCS-CON-2-COAAT 3ADT220090R2 DCS Thyristor Power Converters accessories
  • ​ABB SCYC51220 63901075c Control Module
  • Siemens SYNCHRONOUS SERVOMOTOR 1FK6084-6AZ21-9ZZ9-Z S05
  • Siemens SYNCHRONOUS SERVOMOTOR 1FK6063-6AF71-1EH0
  • FOXBORO FBM241/b/c/d Discrete I/O Interface Modules
  • FOXBORO FBM242, Externally Sourced, Discrete Output Interface Module
  • FOXBORO FBM244, 0 to 20 mA I/O Interface Module with HART Support
  • FOXBORO FBM245, 0 to 20 mA I/O Interface Module with HART Support
  • FOXBORO FBM247, Current/Voltage Analog/Digital/Pulse I/O Configurable Interface Module
  • FOXBORO FBM218 HART Communication Redundant Output Interface Module
  • FOXBORO FBM219 Discrete I/O Interface Module
  • FOXBORO FBM222, Redundant PROFIBUS Communication Interface Module
  • FOXBORO FBM227, 0 to 10 V dc, Contact/dc I/O Interface Module
  • FOXBORO FBM228 FOUNDATION fieldbus Interface Module
  • FOXBORO FBM229 DeviceNet Communication Interface Module
  • FOXBORO FBM230 Field Device System Integrator Module
  • FOXBORO FBM231 Field Device System Integrator Module
  • FOXBORO FBM237, 0 to 20 mA Output Interface Module
  • FOXBORO FBM238, Digital 24DI/8DO Mixed Interface Module
  • FOXBORO FBM239, Discrete 16DI/16DO Interface Module
  • FOXBORO FBM240, Redundant with Readback, Discrete Output Interface Module
  • foxboro FBM208 Redundant with Readback, 0 to 20 mA I/O Interface Module
  • FOXBORO FBM214b HART Communication Input Interface Module
  • FBM215 HART Communication Output Interface Module
  • FBM216b HART Communication Redundant Input Interface Module
  • FOXBORO FBMSVH valve power amplifier card
  • foxboro FBM201/b/c/d Analog Input 0 to 20 mA, 0 to 100 mV, 0 to 5 V, 0 to 10
  • FOXBORO FBM202 Thermocouple/mV Input Interface Module
  • FOXBORO FBM204 0 to 20 mA I/O Interface Module
  • foxboro FBM206 Pulse Input Interface Module
  • FBM207/b/c Voltage Monitor/Contact Sense Input Interface Modules FBM208
  • 0 to 20 mA I/O Interface Module FBM211 FOXBORO
  • FOXBORO P0916FJ 3M Communication cable
  • ALSTOM ALSPA CE80-20 Bus Interface unit
  • Display Controller Rolls-Royce MPCF1-10.4
  • ROCKWELL 2094-BC07-M05-S Kinetix 6000 Integrated Axis Module
  • GE IGBT ProX690-1E1-0W0H0 Phase-controlled control module of gas compression unit
  • ​ALSTOM MVTU11K1CD0751G Control relay
  • ALSTOM MVTU12K1CD0751G Control relay
  • triconex 3382 Pulse Input Module, Enhanced
  • triconex 3451 Solid-State Relay Output Module
  • triconex Digital Output Module, Supervised 3411
  • triconex Digital Output Module 3401
  • triconex Digital Input Module, High Resolution 3311
  • triconex Digital Input Module 3301
  • triconex 3482 High-Current Analog Output Module
  • triconex Model 3481 Analog Output Module
  • Triconex 9793-610F Analog Input/Digital Input Termination Panels Kit, Hazardous Location
  • Triconex 9573-610F Digital Input Termination Panel Kit, Hazardous Location
  • Triconex 2483 Analog Output Baseplate Kit, HART 2483A
  • Triconex 2481 Analog Output Baseplate Kit
  • Triconex 2480A-F Analog Output Baseplate Kit, Hazardous Location
  • Triconex 2451 Solid-State Relay Output Baseplate Kit
  • Triconex 2402-F Digital Output Baseplate Kit, High Voltage 2402A-F
  • Triconex 2401 Digital Output Baseplate Kit 2401H 2401L
  • Triconex 2381 Pulse Input Baseplate Kit 2381A
  • Triconex 2361 Analog Input/Digital Input Baseplate Kit
  • Triconex 2354 Analog Input Baseplate Kit, HART 2354A
  • Triconex 2352A-F Analog Input Baseplate Kit, Hazardous Location
  • Triconex 2352 Analog Input Baseplate Kit for TC, RTD, and 4-20mA (requires 2 of part number 9764-510F)
  • Triconex 2351 Analog Input Baseplate Kit
  • Triconex 2342 Analog Input/Digital Input Baseplate Kit External Termination 2342A-F
  • Triconex 2302-F Digital Input Baseplate Kit, High Voltage 2302A-F
  • Triconex 2301 Digital Input Baseplate Kit
  • Triconex 2292 I/O Bus Termination Kit, MP Baseplate
  • Triconex 2291 I/O Bus Termination Kit, I/O Baseplate
  • Triconex 2281 I/O Bus Extender Module Kit
  • Triconex 2211 Communications Integration Module Baseplate Kit
  • Triconex 2201 Communications Module Baseplate Kit
  • Triconex 2101 Main Processor Baseplate Kit
  • Triconex 5483 Analog Output TriPak, HART 5483A
  • Triconex 5382A Pulse Input TriPak, Enhanced, Hazardous Location
  • Triconex 5382-1 Pulse Input TriPak, Enhanced
  • Triconex 5451 Solid-State Relay Output TriPak
  • Triconex 5402-F Digital Output TriPak, High Voltage
  • Triconex 5411H Digital Output TriPak, Supervised, High Current
  • Triconex Digital Output TriPak, Low Current 5401L
  • Triconex Digital Output TriPak 5401
  • Triconex Digital Input TriPak, High Voltage 5302-F
  • Triconex Digital Input TriPak, High Resolution, High Voltage 5312-F
  • Triconex Digital Input TriPak, High Resolution 5311
  • Triconex Digital Input TriPak 5301
  • SAR 12 029.379519 GE Ring antenna CV(Restricted products)
  • Triconex Analog Output Tripak High-Current 5482-1
  • Triconex Analog Output TriPak 5481-1
  • Triconex Analog Input TriPak HART Hazardous Location 5354A 5354AS2
  • Triconex Analog Input TriPak HART 5354 5354S2
  • Triconex Analog Input Tripak RTD/TC/4-20 mA 5352 5352S2
  • Triconex Analog Input/Digital Input TriPak 5361 5361S2
  • Triconex Analog Input TriPak 5351 5351S2
  • Triconex Communication Module TriPak 5201 5201S2
  • Triconex Communications Integration Module TriPak 5211 5211S2
  • triconex Main Processor TriPak 5101 5101S2
  • TRICONEX 2211 Discrete input/output module
  • CIM3211 Triconex Tricon Communication Model
  • triconex Communication Module cm3201
  • MICRO INNOVATIONDISPLAY INTERFACE PANLE MC2-442-57CQB-1-2G
  • ABB NextMove ESB-2 motion controller
  • IS200SSCHAH2A GE COMMUNICATION TERMINATION TERMIINAL
  • GE IS200WREAH1A PROTE INTERFACE BOARD, EMERG
  • GE IS420UCSCH1B Processing Module UCSC QUAD CORE 1.2GHZ 4GB CONTROLLER
  • UniOP eTOP33C HMI touch unit Product Overview
  • ABB DRIVEMONITOR VERSION 4000 DRIVE RBOX316-ABB-00
  • MOTOROLA MVME5110 VMEbus Single Board Computer Specification
  • GE Grid Solutions Feeder Protection System 350-E-P5-S5-H-E-E-N-N-4E-D-N
  • ABB AFS670 19" Ruggedized Switch AFS670-EREEDDDSSEEEEEEEPZYX05.1.0
  • ABB P8461 digital output 24/48V DC UNIT
  • ABB SCC-K Converter-Without Any Accessories Included Advance
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • ALSTOM BINARY INPUT BOARD 23BI61R1LF 1KWU300080 R1001E
  • ALSTOM LOCAL CONTROL PANEL DRWLM028-Q69-LCP-02S WITCH WIT AC120A
  • MOOG D136-002-005 MSC I and MSC II Motion Controllers D136002005
  • Honeywell CC-PAIX02 I/O Module Sizes High-level AI w/o HART - Differential
  • KEBA PI 050/A DC-link power supply PI050/B keplast i1000
  • WOODWARD 9907-1213 TM-25LP Single Coil Extend
  • GE GDS1168-FF-HCS-NF ALSTOM Power unit
  • GE control board GDS1168-SFP-HCS-NF (PIBE) PLX111909955 ALSTOM Power unit
  • GE IS400JPDMG1A PDM General Electric 28VDC