ABB 3BHB019265R0410 acs6000 Controller unit
ABB 3BHB019265R0410 acs6000 Controller unit
AMC circuit board Application and Motor Controller
The digital signal processor is the heart of the control system of the drive. A separate AMC circuit
board is assigned to the line-side rectifier (AFE) and the motor inverter (INU) of the drive.
AFE Active Front End
The AFE, also referred to as ARU (Active Rectifier Unit), is the line-side rectifier of the drive that
enables four-quadrant operation and reactive power compensation.
Converter Short form for ACS2000 frequency converter
Cluster A cluster is a synonym for a group of hardware modules of the drive control system.
DDCS Distributed drive control system
DDCS is an acronym for a serial communication protocol designed for data transfer via optical
fibers.
Drive Short form for ACS2000 frequency converter
Drive system The drive system includes all equipment used to convert electrical into mechanical power to give
motion to the machine.
DriveBus Communication link dedicated for ABB drives
DriveDebug DriveDebug is part of ABB’s DriveWare® software tools for drives using the DDCS communications
protocol. DriveDebug runs on computers with Windows® operating systems. DriveDebug is a
specialist’s tool used to diagnose, tune and troubleshoot ABB drives.
DriveWindow DriveWindow is a DriveWare® product. DriveWindow is a 32 bit Windows® application for
commissioning and maintaining ABB drives equipped with optical communication links.
DriveMonitor DriveMonitor is a monitoring and diagnostics system that allows secure access to the drive via the
internet from a remote location. DriveMonitor provides long-term monitoring functions that allow
to infer equipment status and improve equipment performance.
Equipment Frequency converter and related equipment
EMC Electromagnetic compatibility
All measures to suppress electromagnetic disturbances caused by different electrical equipment in
the same electromagnetic environment, and to strengthen the immunity of the equipment to such
disturbances.
FE Functional earth
Ground Earth
To ground The conducting path (eg, conductor) between the electric equipment (eg, frequency converter) and
the earth. The electric equipment is connected to the earth, eg, by a grounding set or a grounding
switch.
GTO Gate turn-off thyristor
IGBT Insulated gate bipolar transistor
INU Inverter unit of the drive. The INU converts the DC voltage to the required AC motor voltage and
frequency.
I/O module Term of ABB’s S800 I/O system. The I/O module is an active input or output device for digital or
analog signals.
Line voltage RMS voltage of the main power supply of the drive
MCB Main circuit breaker
The MCB is a major protection device of the drive system and connects / disconnects the main
power supply to the drive. The MCB is controlled entirely by the drive.
PCB Printed circuit board
PCC Point of common coupling. The PCC is the point in the electrical power supply system where the
responsibility of the utility changes to the industrial customer. The utility is responsible to provide
clean voltage and current with respect to harmonic distortion up to the PCC. The industrial
customer is responsible not to distort voltage and current by its electrical systems.
PE Protective earth
Warning
Only qualified electrical personnel familiar with the construction/ operation of this equipment and the hazards involved should install, adjust, operate, and/or service this equipment. Read and understand this guide in its entirety before proceeding. Failure to observe this precaution could result in severe bodily injury or, in extreme cases, loss of life.
WarningYou must provide an external, hand-wired emergency stop circuit outside the programmable controller circuitry. This circuit must disable the system in case of improper operation. Uncontrolled machine motion may result if this procedure is not followed. Failure to observe this precaution could result in bodily injury.
Caution
The card contains static-sensitive components. Careless handling may severely damage the card. Do not touch any of the connectors or pins on the card. When not in use, the card should be stored in an anti-static bag. Failure to observe this precaution could result in damage to or destruction of the equipment
UN 6000 3BHE026284R0101 UA D215 A101 15V, 500V
CSI Converter Signal Interface
for D5 UN6800 & UNL 13300
UN 6000 3BHE026284R0102 UA D215 A102 15V, 1000V
CSI Converter Signal Interface
for D5 UN6800 & UNL 13300
UN 6000 3BHE026284R0104 UA D215 A104 30V, 500V CSI Converter Signal Interface for UNL14300
UN 6000 3BHE026284R0105 UA D215 A105 30V, 1000V CSI Converter Signal Interface for UNL14300
UN 6000 3BHE026284R0106 UA D215 A106 30V, 1500V CSI Converter Signal Interface for UNL14300
UN 6000 3BHE051993R0001 Adapter plate UA D215 to UA D209
CSI Adapter plate for UA D209
replacement with UA D215
UN 6000 3BHE023784R2030 PP D113 B01-20-111000 AC800PEC controller (FPGA Size 10K) 3OM X
UN 6000 3BHE023784R2330 PP D113 B01-23-111000
AC800PEC controller
(FPGA Size 10K) Profibus, 3OM
UN 6000 3BHE023784R2630 PP D113 B01-26-111001
AC800PEC controller
(FPGA Size 10K) Modbus RTU, 3OM
UN 6000 3BHE023784R2530 PP D113 B01-25-111001
AC800PEC controller
(FPGA Size 10K) Modbus TCP, 3OM
UN 6000 3BHE023126R0020 AF D242 A
CCP Converter Control Panel
UNITROL 6000 X-power
UN 6000 3BHE023126R0010 AF D242 A SCP Service Control Panel
UN 6000 3BHE022293R0101 PC D232 A: PEC80-CIO CIO Combined Input Output X
UN 6000 3BHE032025R0101 PC D235 A: PEC80-CIO FU
CIO Combined Input Output
FPGA (standard)
ABB 3BHE006805R0002 DDC779BE02 Circuit Board
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2025 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,