ABB RER103 Bus Connection Module
ABB RER103 Bus Connection Module
• Feeder terminal for protection, control, measurement and supervision of medium voltage networks
• New application areas for power quality measurement, protection, capacitor bank protection and control and motor protection
• Voltage and current measurement via con ventional measuring transformers or cur rent and voltage sensors
• Fixed man-machine interface including a large graphic display, or an external display module for flexible switchgear installation
• Extended functionality including protec tion, control, measurement, communica tion, power quality and condition monitoring
• Protection functions including e.g. non directional and directional overcurrent and earth-fault protection, residual voltage, overvoltage and undervoltage protection, thermal overload protection, CBFP and auto-reclosing
• Control functions including local and remote control of switching objects, status indication of the switching objects and interlockings on bay and station level
• Measurement of phase currents, phase-to phase and phase-to-neutral voltages, residual current and voltage, frequency, power factor, active and reactive power and energy, etc.
• Condition monitoring including circuit breaker condition monitoring, trip circuit supervision and internal self-supervision of the feeder terminal
• Additional functions including synchro check, frequency protection, capacitor bank protection and control, measurement of current and voltage harmonics
• RTD/analogue module for temperature measurement, current/voltage measure ment and mA-outputs • Communication over two communication interfaces: one for local communication with a PC and the other for remote commu nication via a substation communication system
• Part of the ABB Substation Automation system
IS220PDIAH1A IS220PDIAH1B Contact Inputs: 24 discrete inputs
IS220PDIIH1A IS220PDIIH1B Isolated Contact Inputs: 16 discrete inputs
IS220PDIOH1A IS220PDIOH1B Discrete Inputs/Outputs: 24 Contact Inputs and 12 Form-C Mechanical Relays
IS220PDOAH1A IS220PDOAH1B Contact outputs: 12 relays with status feedback
IS220PAICH1A IS220PAICH1B Analog Input/Output: 10 analog inputs and 2 analog outputs
IS220PAICH2A IS220PAICH2B Analog Input/Output 200 mA output
IS220PAOCH1A IS220PAOCH1B Analog output: 8, 0-20 mA output
IS220PPDAH1A IS220PPDAH1B Power Distribution System Feedback
IS220PTCCH1A IS220PTCCH1B Thermocouple: 12 Combustion Optimization Inputs, 1 Cold Junction
IS220PTCCH2A IS220PTCCH2B Thermocouple: 12 General Purpose Industrial Inputs, 1 Cold Junction
IS220PRTDH1A IS220PRTDH1B RTD Input: 8 RTDs
IS220PSCAH1A IS220PSCAH1B Serial communication: 6 channels
IS220PCNOH1A IS220PCNOH1B CANopen® Communication
IS220PPRFH1A IS220PPRFH1B PROFIBUS® Communication
IS220PHRAH1A IS220PHRAH1B Hart® Analog Input/Output: 10 AI (V/I Input) and 2 AO (0-20 mA Output)
Using HART Communication
IS220PCAAH1A IS220PCAAH1B Core Analog Input/Output for Heavy Duty Gas Turbines
IS220PCLAH1A IS220PCLAH1B Core analog input/output for aeroderivative turbines
IS220PSVOH1A IS220PSVOH1B Servo Control: 2 Outputs, 8 LVDTs and 2 Pulse Rate Inputs
IS220PTURH1A IS220PTURH1B Turbine Input/Output: Primary Turbine Protection
IS220PPRAS1A-HIA IS220PPRAS1B Turbine Input/Output: Turbine Backup Protection
IS220PPROH1A IS220PPROH1B Turbo Input/Output: Turbo Backup Protection
Delivery:
Warranty:
All our products are covered by our own warranty.
Payment method:
Quick Quote: Receive price and availability today!
Replacing an electrical equipment unit in a plant is a complex task that requires careful planning and execution to ensure safety and minimize downtime. Here is a general step-by-step guide on how to replace electrical equipment in a plant:
Pre-Planning:
Safety Precautions:
Shutdown Procedures:
Disconnection:
Removal of Existing Equipment:
Installation of New Equipment:
Testing and Commissioning:
Documentation:
Training:
Startup:
Throughout the process, it’s important to work closely with a team that includes electrical engineers, technicians, and maintenance staff. Communication is key to a successful equipment replacement. Additionally, always adhere to local electrical codes and standards to ensure compliance and safety. If the task is beyond the expertise of in-house staff, consider hiring a professional contractor experienced in industrial electrical work.
Obtaining industrial automation programming software typically involves the following steps:
Identify Your Needs:
Research Software Options:
Contact Equipment Manufacturers:
Purchase or Download:
Academic or Evaluation Versions:
Open Source Options:
Licensing:
Training and Support:
Legal and Compliance:
Installation and Setup:
Here are some common ways to obtain industrial automation programming software:
Remember to keep your software updated to benefit from the latest features and security patches. Also, ensure that you have the necessary backup and recovery procedures in place to protect your programming work.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.
COPYRIGHT© 2003-2025 Copyrighted
Phone(WeChat/Whatsapp)
+086-181 4410 0983
No 1134 Jimei North Road,
Hong Kong Office:
Guan Tang District, Hong Kong,