Isolated relay output contacts NO, 2-pole connection
560NUS04 - Integrated unmanaged switch with 4 ports
Fibre optic coupler for glass-fibre optic cable with emission wave length of 820 nm. Fiber optic connection with bayonet socket BFOC/2.5 (IEC-SC86B)
560NUS12 - Integrated unmanaged switch with 2 SFP slots
Unmanaged switch
4x 10/100 BaseT port (electrical)
Linear network structure supported
Can be used with rack types 560MPR01, 560MPR03, 560SFR02.
Unmanaged switch
2x SFP slot, without optical transmitter/receiver
Additional SFP modules are required (see 560NFOxx)
2x 10/100 BaseT port (electrical)
Linear network structure supported560NMS34 - Integrated managed switch with 1 SDSL-port and 4 Ethernet ports
Integrated managed layer-2-switch
4x 10/100 BaseT port (RJ45, electrical, auto negotiating)
1x SDSL-port for copper wire
Provides redundant topologies by the (Rapid) Spanning Tree Protocol (RSTP)
1x RS-232 port suitable for serial protocols
Analog signal represented digitally by 11 bit + sign
Selectable current outputs: +/-2.5 mA; +/-5 mA; +/-10 mA; +/-20 mA; +4...20 mA
Analog measured values (AMI)
Measured floating point information (MFI)
AD converter resolution: 16 bit
Measuring ranges: +/-2 mA; +/-5 mA; +/-10 mA; +/-20 mA; +/-40 mA; +/-2 V DC; 0...20 V DC
Analog measured values (AMI)
Measured floating point information (MFI)
AD converter resolution: 16 bit
Measuring ranges: +/-2 mA; +/-5 mA; +/-10 mA; +/-20 mA; +/-40 mA
Two test and switching circuits
Auxiliary test voltage 24...60 V DC
16 relay contacts, 2 groups of 8 outputs with common return
Max. switching voltage: 150 V DC
Max. breaking current: 2 A @ 60 V DC
Analog input/output modules
23AA21 - Analog output, 2 channels with potential isolation
Via the analog output board 23AA21 analog control outputs for sequential or closed loop control, display instruments, measurand recorders etc. can be connected to the RTU560.
560AIR01 - Analog input, 8 channels
The 560AIR01 module records up to 8 analog measured values. The module 560AIR01 is able to process the following types of signals:
560AIR02 - Analog input, 8 channels
The 560AIR02 module records up to 8 analog measured values. The module 560AIR02 is able to process the following types of signals:
Command output modules
23BA23 - Command output monitoring (1 out of n) check
The 23BA23 board is intended for use in the RTU560 product line. The 23BA23 board should be installed if the output circuit of an object command has to be checked before the actual command is given.
23BA40 - Command output module
The 23BA40 can be used for the following types of signal: object commands with single or double contact outputs, regulation commands, digital set points, bitstring output, 1, 2 or 16 bit.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.