Remote Terminal Unit RTU560
Substation automation product for transmission and sub-transmission. RTU560 represents high-end network interfacing - offering maximum flexibility with the highest number of supported protocols for sub and host communications. Designed to handle the highly complex systems in grid automation and control interfacing. RTU560 connects to all kinds of IEDs, parallel I/Os, serial connected and communication via IEC 68150. All this real time data can then be transmitted to your central SCADA systems for critical actions - protecting your primary equipment from overloading of the grid. Optimize your investments with our long life cycle policy and benefit from our agile migration concepts.
RTU560 product line increases availability with a flexible redundancy concept which is suitable for all types of redundant requirements. Redundant communication units can be replaced even during operation, ensuring a reliable system.
23BE40 - Binary input, 16 channels
Allocation of an input signal to a processing function can be done according to the rules of configuration.
16 channel potential isolated inputs, without common return
Process voltage: 110...125 V DC and 220...250 V DC
23BE23 - Binary input, 16 channels, LED's
To be used for single indications, double indications, digital measurands and pulse counters.
Resolution: 1 ms
Process voltage: 24...60 V DC
LED signal for each input
560BIR01 - Binary input, 8 channels, LED's
Binary input module 560BIR01
(R2: 110/125VDC)
Support of 110/125 VDC process voltage in rack mounting
110/125V module
23BE50 - Binary input, 64 channels, LED's
To be used for single indications, double indications, digital measurands and pulse counters.
Resolution: 1 ms
Process voltage: 24...60 V DC
LED signal for each input
23BA20 - Binary output, 16 channels
16 output contacts configured as:
1-pole command
2-pole command
1.5-pole command in configuration with 23BA23
Operating voltage 24...60 V DC, 60 W
Imax.: 2 A with 24 V DC (ohmic load)
560BOR01 - Binary output, 16 channels
To be used for control of 16 binary process signals using relay contacts.
16 relay contacts, 2 groups of 8 outputs with common return
Max. switching voltage: 150 V DC
Max. breaking current: 2 A @ 60 V DC
560HMR01 - Human machine interface (HMI)
Interface board to RTU560 integrated web HMI
Windows 7 Professional (32 bit)
2x Ethernet interface (10/100BaseT)
4x USB ports for keyboard and mouse
1x VGA port for monitor
1x Stereo audio-out
560CMR01 – Communication Unit
Central module of the RTU560 with ARM based platform
2x serial communication interfaces (RS-232 or RS-485) for local/remote communication
2x Ethernet interface (10/100BaseT) SD card with licenses and functions adaptable to customer requirements
1 x Micro-USB interface for webserver access
560CMR02 - Communication unit
2x ETH, 6 serial (RS232/485)
USB interface for Webserver access
Powerful CMU platform (factor 3-4)
Considerable memory (128 MB)
560PSR00
Input voltage 24...60 V DC
Output voltage: 5 and 24 V DC
Suitable for redundant power supply in 560MPR03/560SFR02
560PSU01
Input voltage 110...220 V DC
Output voltage: 5 and 24 V DC
Suitable for redundant power supply in 560MPR03/560SFR02
560PSU02
Input voltage: 48...220 V DC
Output voltage: 5 and 24 V DC
Suitable for redundant power supply in 560MPR03/560SFR02
Binary input/output modules
23BE40 - Binary input, 16 channels
Allocation of an input signal to a processing function can be done according to the rules of configuration.
16 channel potential isolated inputs, without common return
Process voltage: 110...125 V DC and 220...250 V DC
560BIR01 - Binary input, 16 channels, LED's
Binary input module 560BIR01
R1: 24...60VDC
R2: 110/125VDC
24...60 VDC and support of 110/125 VDC process voltage in rack mounting
560BOR01 - Binary output, 16 channels
To be used for control of 16 binary process signals using relay contacts.
16 output contacts configured as 16 single contact outputs or 8 double contact outputs
Switching voltage: 24...220 V DC / 250 V AC
Max. switching capacity: 120 W (DC)
Max. switching current: 300 mA at 110 V DC, 200 mA at 220 V DC (L/R = 40 ms)
Isolated relay output contacts NO, 2-pole connection
560NUS04 - Integrated unmanaged switch with 4 ports
Fibre optic coupler for glass-fibre optic cable with emission wave length of 820 nm. Fiber optic connection with bayonet socket BFOC/2.5 (IEC-SC86B)
560NUS12 - Integrated unmanaged switch with 2 SFP slots
Unmanaged switch
4x 10/100 BaseT port (electrical)
Linear network structure supported
Can be used with rack types 560MPR01, 560MPR03, 560SFR02.
Unmanaged switch
2x SFP slot, without optical transmitter/receiver
Additional SFP modules are required (see 560NFOxx)
2x 10/100 BaseT port (electrical)
Linear network structure supported560NMS34 - Integrated managed switch with 1 SDSL-port and 4 Ethernet ports
Integrated managed layer-2-switch
4x 10/100 BaseT port (RJ45, electrical, auto negotiating)
1x SDSL-port for copper wire
Provides redundant topologies by the (Rapid) Spanning Tree Protocol (RSTP)
1x RS-232 port suitable for serial protocols
Analog signal represented digitally by 11 bit + sign
Selectable current outputs: +/-2.5 mA; +/-5 mA; +/-10 mA; +/-20 mA; +4...20 mA
Analog measured values (AMI)
Measured floating point information (MFI)
AD converter resolution: 16 bit
Measuring ranges: +/-2 mA; +/-5 mA; +/-10 mA; +/-20 mA; +/-40 mA; +/-2 V DC; 0...20 V DC
Analog measured values (AMI)
Measured floating point information (MFI)
AD converter resolution: 16 bit
Measuring ranges: +/-2 mA; +/-5 mA; +/-10 mA; +/-20 mA; +/-40 mA
Two test and switching circuits
Auxiliary test voltage 24...60 V DC
16 relay contacts, 2 groups of 8 outputs with common return
Max. switching voltage: 150 V DC
Max. breaking current: 2 A @ 60 V DC
Analog input/output modules
23AA21 - Analog output, 2 channels with potential isolation
Via the analog output board 23AA21 analog control outputs for sequential or closed loop control, display instruments, measurand recorders etc. can be connected to the RTU560.
560AIR01 - Analog input, 8 channels
The 560AIR01 module records up to 8 analog measured values. The module 560AIR01 is able to process the following types of signals:
560AIR02 - Analog input, 8 channels
The 560AIR02 module records up to 8 analog measured values. The module 560AIR02 is able to process the following types of signals:
Command output modules
23BA23 - Command output monitoring (1 out of n) check
The 23BA23 board is intended for use in the RTU560 product line. The 23BA23 board should be installed if the output circuit of an object command has to be checked before the actual command is given.
23BA40 - Command output module
The 23BA40 can be used for the following types of signal: object commands with single or double contact outputs, regulation commands, digital set points, bitstring output, 1, 2 or 16 bit.
All new products and surplus products of the industrial intelligence industry, as well as the discontinued products of the original manufacturers. We are not an authorized distributor or representative of any of the above manufacturers (except for brand authorization). The trademarks, brand names and brands appearing in this agreement are the property of their respective manufacturers.