The digitised measured variables derived from the primary system quantities are continuously compared by the processing unit
216VC62a with the pick-up settings of the protection functions. If
a protection function picks up, the corresponding signal or tripping command is transmitted via the B448C bus to the 216AB61
O/P unit resp. to the 216DB61 I/O unit. The allocation of the signals and tripping commands at the O/P’s of the protection functions to the various channels of the 216AB61 output unit or of the
216DB61 I/P signal and tripping unit is also determined by the
software installed in the 216VC62a processor unit.
The output signals from the 216AB61 unit (signalling channels)
and 216DB61 unit (trip channels) control the auxiliary relays
K1...K16 of the 216GA61 O/P relay unit or 216GA62 tripping relay unit. The auxiliary relays' contacts are potentially-free and
wired to terminals for connection to external signalling and tripping circuits.
The external input signals connected to the protection energise
the auxiliary relays K1...K16 in the 216GE61 I/P relay unit. The
potentially-free contacts of K1...K16 transmit the external signals
to the 216DB61 unit and thence to the B448C bus. By appropriate configuration of the software in the 216VC62a processing
unit, external signals can be assigned to the various protection
functions, e.g. for logical combination (interlocking and blocking)
with trip signals or for exciting the tripping channels 1...8.
Tripping circuits 1...8 can be directly energised by all or just
some of the I/P channels 1...10 (K1...K10) of 216GE61 via the
diode matrix (tripping logic) of 216GA62 (see Section 2.6.).
Provision is also made for some of the channels 9...16
(K9...K16) of 216GE61 to be used for supervising the external
tripping circuits 1...8 instead of for the connection of external inputs. This is an option, which must be specified in the order to
enable the corresponding wiring to be included when engineering the protection.
Tension sensing PFCL, PFEA, PFTL series
Bailey INFI9, IMDSI02 IMMFP03 IPSYS01
Panel 800 Touch screen PP846 PP836 PP865A
AC 800PEC inverter cabinet controller
red/green LED for battery status
Woodward 5463-190
GJR5253000R0160 ABB
OVATION IC31197G01
2711-T10C15 2711-T10C15
8440-1706B
Analog output
• Allen-Bradley DF1 interface, CI534V4, 2 ch. Up to 5
• Telecontrol & SPA bus, CI535Vxx 13 Up to 5
Voltage regulator, SR511 (Tot. 2) 1
Battery charger, SB510 Up to 2
Cabinets 3, 8,11
RM500V1, IP21, IP41 or IP54: WxDxH 800x512x2125 mm,
(31.5"x20.2"x83.7")
RM500V2, IP21, IP41 or IP54: WxDxH 700x637x2225 mm,
(27.6"x25.1"x87.6")
power module
• V.24/RS232 interface, CI531, 2 ch. 5, 14 Up to 4
• MasterBus 300/300E interface
- Without slave CPU, CS513A/SC510 Up to 2
TCP/IP CI546/SC510
- With slave CPU, CS513A/SC520 6,7 Up to 6
• GCOM interface, CI543/SC510 10 Up to 5